An inverse fitting strategy to determine the constrained mixture model parameters: application in patient-specific aorta.
Autor: | Navarrete Á; Departamento de Ingeniería Mecánica, Universidad de Santiago de Chile, USACH, Santiago de Chile, Chile., Utrera A; Departamento de Ingeniería Mecánica, Universidad de Santiago de Chile, USACH, Santiago de Chile, Chile., Rivera E; Departamento de Ingeniería Mecánica, Universidad de Santiago de Chile, USACH, Santiago de Chile, Chile., Latorre M; Center for Research and Innovation in Bioengineering, Universitat Politècnica de València, València, Spain., Celentano DJ; Departamento de Ingeniería Mecánica y Metalúrgica, Pontificia Universidad Católica de Chile, Santiago de Chile, Chile., García-Herrera CM; Departamento de Ingeniería Mecánica, Universidad de Santiago de Chile, USACH, Santiago de Chile, Chile. |
---|---|
Jazyk: | angličtina |
Zdroj: | Frontiers in bioengineering and biotechnology [Front Bioeng Biotechnol] 2023 Nov 20; Vol. 11, pp. 1301988. Date of Electronic Publication: 2023 Nov 20 (Print Publication: 2023). |
DOI: | 10.3389/fbioe.2023.1301988 |
Abstrakt: | The Constrained Mixture Model (CMM) is a novel approach to describe arterial wall mechanics, whose formulation is based on a referential physiological state. The CMM considers the arterial wall as a mixture of load-bearing constituents, each of them with characteristic mass fraction, material properties, and deposition stretch levels from its stress-free state to the in-vivo configuration. Although some reports of this model successfully assess its capabilities, they barely explore experimental approaches to model patient-specific scenarios. In this sense, we propose an iterative fitting procedure of numerical-experimental nature to determine material parameters and deposition stretch values. To this end, the model has been implemented in a finite element framework, and it is calibrated using reported experimental data of descending thoracic aorta. The main results obtained from the proposed procedure consist of a set of material parameters for each constituent. Moreover, a relationship between deposition stretches and residual strain measurements (opening angle and axial stretch) has been numerically proved, establishing a strong consistency between the model and experimental data. Competing Interests: The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest. (Copyright © 2023 Navarrete, Utrera, Rivera, Latorre, Celentano and García-Herrera.) |
Databáze: | MEDLINE |
Externí odkaz: |