Development and Human Factors Evaluation of a Portable Auditory Localization Training System.
Autor: | Thompson BS; United States Military Academy, West Point, NY, USA., Lee K; Virginia Polytechnic Institute and State University (Virginia Tech) and Hearing, Ergonomics & Acoustics Resources (HEAR) LLC, Blacksburg, VA, USA., Casali JG; Virginia Polytechnic Institute and State University (Virginia Tech) and Hearing, Ergonomics & Acoustics Resources (HEAR) LLC, Blacksburg, VA, USA., Cave KM; Womack Army Medical Center, Fort Liberty, NC, USA. |
---|---|
Jazyk: | angličtina |
Zdroj: | Human factors [Hum Factors] 2024 Oct; Vol. 66 (10), pp. 2393-2408. Date of Electronic Publication: 2023 Nov 30. |
DOI: | 10.1177/00187208231209137 |
Abstrakt: | Objective: To design and develop a Portable Auditory Localization Acclimation Training (PALAT) system capable of producing psychoacoustically accurate localization cues; evaluate the training effect against a proven full-scale, laboratory-grade system under three listening conditions; and determine if the PALAT system is sensitive to differences among electronic level-dependent hearing protection devices (HPDs). Background: In-laboratory auditory localization training has demonstrated the ability to improve localization performance with the open (natural) ear, that is, unoccluded, and while wearing HPDs. The military requires a portable system capable of imparting similar training benefits as those demonstrated in laboratory experiments. Method: In a full-factorial repeated measures design experiment, 12 audiometrically normal participants completed localization training and testing using an identical, optimized training protocol on two training systems under three listening conditions (open ear, TEP-100, and ComTac™ III). Statistical tests were performed on mean absolute accuracy score and front-back reversal errors. Results: No statistical difference existed between the PALAT and laboratory-grade DRILCOM systems on two dependent localization accuracy measurements at all stages of training. In addition, the PALAT system detected the same localization performance differences among the three listening conditions. Conclusion: The PALAT system imparted similar training benefits as the DRILCOM system and was sensitive to HPD localization performance differences. Application: The user-operable PALAT system and optimized training protocol can be employed by the military, law enforcement, and various industries, to improve auditory localization performance in conditions where auditory situation awareness is critical to safety. |
Databáze: | MEDLINE |
Externí odkaz: |