Neuronal functional connectivity is impaired in a layer dependent manner near the chronically implanted microelectrodes.

Autor: Chen K, Forrest A, Gonzalez Burgos G, Kozai TDY
Jazyk: angličtina
Zdroj: BioRxiv : the preprint server for biology [bioRxiv] 2023 Nov 06. Date of Electronic Publication: 2023 Nov 06.
DOI: 10.1101/2023.11.06.565852
Abstrakt: Objective: This study aims to reveal longitudinal changes in functional network connectivity within and across different brain structures near the chronically implanted microelectrode. While it is well established that the foreign-body response (FBR) contributes to the gradual decline of the signals recorded from brain implants over time, how does the FBR impact affect the functional stability of neural circuits near implanted Brain-Computer Interfaces (BCIs) remains unknown. This research aims to illuminate how the chronic FBR can alter local neural circuit function and the implications for BCI decoders.
Approach: This study utilized multisite Michigan-style microelectrodes that span all cortical layers and the hippocampal CA1 region to collect spontaneous and visually-evoked electrophysiological activity. Alterations in neuronal activity near the microelectrode were tested assessing cross-frequency synchronization of LFP and spike entrainment to LFP oscillatory activity throughout 16 weeks after microelectrode implantation.
Main Results: The study found that cortical layer 4, the input-receiving layer, maintained activity over the implantation time. However, layers 2/3 rapidly experienced severe impairment, leading to a loss of proper intralaminar connectivity in the downstream output layers 5/6. Furthermore, the impairment of interlaminar connectivity near the microelectrode was unidirectional, showing decreased connectivity from Layers 2/3 to Layers 5/6 but not the reverse direction. In the hippocampus, CA1 neurons gradually became unable to properly entrain to the surrounding LFP oscillations.
Significance: This study provides a detailed characterization of network connectivity dysfunction over long-term microelectrode implantation periods. This new knowledge could contribute to the development of targeted therapeutic strategies aimed at improving the health of the tissue surrounding brain implants and potentially inform engineering of adaptive decoders as the FBR progresses. Our study's understanding of the dynamic changes in the functional network over time opens the door to developing interventions for improving the long-term stability and performance of intracortical microelectrodes.