Radiation exposure during CT procedures in Tanzania.
Autor: | Ngoye W; Tanzania Atomic Energy Commission, P.O. Box 743, Block J, Njiro, 23114 Arusha, Tanzania., Ndukeki M; Muhimbili National Hospital, Malik Road, P.O. Box 65000, West Upanga, 8920 Dar es Salaam, Tanzania., Muhogora W; Tanzania Atomic Energy Commission, P.O. Box 743, Block J, Njiro, 23114 Arusha, Tanzania., Jusabani A; Aga Khan Medical Centre, P.O. Box 2289, Baraka Obama Road, 11103 Dar es Salaam, Tanzania., Ngaile J; Tanzania Atomic Energy Commission, P.O. Box 743, Block J, Njiro, 23114 Arusha, Tanzania., Ngoya P; Bugando Medical Centre, P.O. Box 1370, Makongoro Road, 33109 Mwanza, Tanzania., Sungura R; Arusha Lutheran Medical Centre, P.O. Box 17047, Fr. Babu Road, Block No. 54 Levolosi, 23104 Arusha, Tanzania., Ngatunga C; Mbeya Zonal Referral Hospital, P.O. Box 419, Hospital Hill Road, 53107 Mbeya, Tanzania., Hashmi N; TMJ Hospital, Mwai Kibaki Road, P.O. Box 20439, Mikocheni, 14112 Dar es Salaam, Tanzania., Makungu H; Muhimbili National Hospital, Malik Road, P.O. Box 65000, West Upanga, 8920 Dar es Salaam, Tanzania., Onoka E; Arusha Lutheran Medical Centre, P.O. Box 17047, Fr. Babu Road, Block No. 54 Levolosi, 23104 Arusha, Tanzania., Amirali M; Muhimbili National Hospital, Malik Road, P.O. Box 65000, West Upanga, 8920 Dar es Salaam, Tanzania., Kileo A; Tanzania Atomic Energy Commission, P.O. Box 743, Block J, Njiro, 23114 Arusha, Tanzania., Makoba A; Tanzania Atomic Energy Commission, P.O. Box 743, Block J, Njiro, 23114 Arusha, Tanzania., Muhulo A; Tanzania Atomic Energy Commission, P.O. Box 743, Block J, Njiro, 23114 Arusha, Tanzania., Ngulimi M; Tanzania Atomic Energy Commission, P.O. Box 743, Block J, Njiro, 23114 Arusha, Tanzania., Balobegwa V; Tanzania Atomic Energy Commission, P.O. Box 743, Block J, Njiro, 23114 Arusha, Tanzania., Edmund E; Tanzania Atomic Energy Commission, P.O. Box 743, Block J, Njiro, 23114 Arusha, Tanzania., Masoud A; Tanzania Atomic Energy Commission, P.O. Box 743, Block J, Njiro, 23114 Arusha, Tanzania., Matulanya M; Tanzania Atomic Energy Commission, P.O. Box 743, Block J, Njiro, 23114 Arusha, Tanzania. |
---|---|
Jazyk: | angličtina |
Zdroj: | Radiation protection dosimetry [Radiat Prot Dosimetry] 2023 Dec 29; Vol. 200 (1), pp. 97-105. |
DOI: | 10.1093/rpd/ncad274 |
Abstrakt: | The aim of this study was to evaluate optimisation status during common computed tomography (CT) procedures by determining values of volume computed tomography dose index (CTDIvol) and dose-length product (DLP) per examination. Patient and exposure data were collected from the CT console during various CT procedures. The results show that variations in CTDIvol and DLP values were mainly because of differences in the techniques used. The 75th percentile values were set as the third quartile of the median CTDIvol or DLP values for all hospitals. These values of 40.9, 9.0, 9.4 and 16.2 mGy for CTDIvol were determined for head, high-resolution chest, abdomen-pelvis and lumbar spine, respectively. The corresponding DLP values for the same sequence of CT procedures were 900, 360, 487 and 721 mGy.cm, respectively. The updated results provide a basis for optimising the procedures of CT in this country. (© The Author(s) 2023. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.) |
Databáze: | MEDLINE |
Externí odkaz: |