Fluoroscopy-based robotics in total hip arthroplasty mitigates laterality-based differences in acetabular cup placement when compared to the manual, fluoroscopic- assisted technique.
Autor: | Ong CB; Department of Orthopaedic Surgery, Orthopaedic and Rheumatologic Institute, Cleveland Clinic Foundation, Cleveland, OH, USA., Buchan GBJ; Department of Orthopaedic Surgery, Orthopaedic and Rheumatologic Institute, Cleveland Clinic Foundation, Cleveland, OH, USA., Hecht Ii CJ; Department of Orthopaedic Surgery, Orthopaedic and Rheumatologic Institute, Cleveland Clinic Foundation, Cleveland, OH, USA., Homma Y; Department of Medicine for Orthopaedics and Motor Organs, Juntendo University Graduate School of Medicine, Tokyo, Japan.; Department of Orthopaedics, Faculty of Medicine, Juntendo University, Tokyo, Japan., Harmon DJ; Department of Orthopaedic Surgery, Orthopaedic and Rheumatologic Institute, Cleveland Clinic Foundation, Cleveland, OH, USA., Kendoff DO; Chefarzt Zentrum für Orthopädie und Unfallchirurgie, HELIOS Kliniken Berlin-Buch, Berlin, Germany., Petterwood J; Department of Orthopaedics, Royal Hobart Hospital, Hobart, TAS, Australia.; Department of Orthopaedics, Calvary Hospital, Hobart, TAS, Australia., Kamath AF; Department of Orthopaedic Surgery, Orthopaedic and Rheumatologic Institute, Cleveland Clinic Foundation, Cleveland, OH, USA. |
---|---|
Jazyk: | angličtina |
Zdroj: | Technology and health care : official journal of the European Society for Engineering and Medicine [Technol Health Care] 2024; Vol. 32 (5), pp. 3693-3701. |
DOI: | 10.3233/THC-231126 |
Abstrakt: | Background: Robotic assistance in total hip arthroplasty (RA-THA) has been shown to minimize laterality-based differences in acetabular cup positioning. Objective: To determine if the use of a novel, fluoroscopy-based RA-THA system mitigates differences in acetabular cup placement between left (L) and right (R) side hip procedures, when compared to manual, fluoroscopic-assisted technique. Methods: We conducted a retrospective review of 106 consecutive mTHA (40 L/66 R) and 102 RA-THA (48 L/54 R) primary direct anterior approach procedures. All cases were performed by a single right-hand-dominant surgeon, for a pre-operative diagnosis of osteoarthritis, avascular necrosis, or rheumatoid arthritis. Outcomes included acetabular cup inclination and anteversion, and the proportion of cups within the Lewinnek safe-zone. Results: The average inclination of mTHA L cases was smaller than that of mTHA R cases (41.10∘± 7.38 vs. 43.97∘± 6.27; p= 0.04). For RA-THA, L and R cup angles were similar. There were fewer overall mTHA hips within the Lewinnek safe-zone compared to RA-THA (0.59 vs. 0.78; p= 0.003), as well as fewer mTHA R cases than RA-THA R cases (0.59 vs. 0.80; p= 0.03) within safe zone. Conclusion: Use of a novel, fluoroscopy-based robotic system mitigates laterality-based differences in acetabular cup placement that were observed in a manual, fluoroscopic-assisted cohort. |
Databáze: | MEDLINE |
Externí odkaz: |