Balloon- vs Self-Expanding Transcatheter Valves for Failed Small Surgical Aortic Bioprostheses: 1-Year Results of the LYTEN Trial.

Autor: Nuche J; Quebec Heart and Lung Institute, Laval University, Quebec City, Quebec, Canada., Abbas AE; Corewell Health East, William Beaumont University Hospital, Royal Oak, Michigan, USA., Serra V; Hospital Universitari Vall d'Hebron, Barcelona, Spain., Vilalta V; Hospital Universitari Germans Trias i Pujol, Badalona, Spain., Nombela-Franco L; Cardiovascular Institute, Hospital Clinico San Carlos, IdISSC, Madrid, Spain., Regueiro A; Clinic Cardiovascular Institute, Hospital Clinic de Barcelona, Institut d'Investigacions Biomèdiques August Pi I Sunyer, University of Barcelona, Barcelona, Spain., Al-Azizi KM; Baylor Scott and White The Heart Hospital Plano, Plano, Texas, USA., Iskander A; SJH Cardiology Associates, Syracuse, New York, USA., Conradi L; University Heart and Vascular Center, Hamburg, Germany., Forcillo J; Centre Hospitalier Universitaire de Montreal, Montreal, Quebec, Canada., Lilly S; OSU Heart and Vascular Research Organization, Richard M Ross Hospital, Columbus, Ohio, USA., Calabuig A; Hospital Universitari Vall d'Hebron, Barcelona, Spain., Fernandez-Nofrerias E; Hospital Universitari Germans Trias i Pujol, Badalona, Spain., Mohammadi S; Quebec Heart and Lung Institute, Laval University, Quebec City, Quebec, Canada., Giuliani C; Quebec Heart and Lung Institute, Laval University, Quebec City, Quebec, Canada., Pelletier-Beaumont E; Quebec Heart and Lung Institute, Laval University, Quebec City, Quebec, Canada., Pibarot P; Quebec Heart and Lung Institute, Laval University, Quebec City, Quebec, Canada., Rodés-Cabau J; Quebec Heart and Lung Institute, Laval University, Quebec City, Quebec, Canada; Clinic Cardiovascular Institute, Hospital Clinic de Barcelona, Institut d'Investigacions Biomèdiques August Pi I Sunyer, University of Barcelona, Barcelona, Spain. Electronic address: josep.rodes@criucpq.ulaval.ca.
Jazyk: angličtina
Zdroj: JACC. Cardiovascular interventions [JACC Cardiovasc Interv] 2023 Dec 25; Vol. 16 (24), pp. 2999-3012. Date of Electronic Publication: 2023 Oct 23.
DOI: 10.1016/j.jcin.2023.10.028
Abstrakt: Background: Data comparing valve systems in the valve-in-valve transcatheter aortic valve replacement (ViV-TAVR) field have been obtained from retrospective studies.
Objectives: The authors sought to compare the 1-year hemodynamic performance and clinical outcomes between balloon-expandable valves (BEV) SAPIEN 3/ULTRA (Edwards Lifesciences) and self-expanding valves (SEV) Evolut R/PRO/PRO+ (Medtronic) in ViV-TAVR.
Methods: Patients with a failed small (≤23 mm) surgical valve undergoing ViV-TAVR were randomized to receive a SEV or a BEV. Patients had a clinical and valve hemodynamic (Doppler echocardiography) evaluation at 1-year follow-up. Study outcomes were defined according to VARC-2/VARC-3 criteria. Intended performance of the valve was defined as mean gradient <20 mm Hg, peak velocity <3 m/s, Doppler velocity index ≥0.25 and less than moderate AR.
Results: A total of 98 patients underwent ViV-TAVR (46 BEV, 52 SEV). At 1-year follow-up, patients receiving a SEV had a lower mean transaortic gradient (22 ± 8 mm Hg BEV vs 14 ± 7 mm Hg SEV; P < 0.001), and a higher rate of intended valve performance (BEV: 30%, SEV:76%; P < 0.001). There were no cases of greater than mild aortic regurgitation. There were no differences in functional status (NYHA functional class >II, BEV: 7.3%, SEV: 4.1%; P = 0.505) or quality of life (Kansas City Cardiomyopathy Questionnaire, BEV: 77.9 ± 21.2, SEV: 81.8 ± 14.8; P = 0.334). No differences in all-cause mortality (BEV: 6.5%, SEV: 3.8; P = 0.495), heart failure hospitalization (BEV: 6.5%, SEV: 1.9%; P = 0.214), stroke (BEV: 0%, SEV: 1.9%; P = 0.369), myocardial infarction (BEV: 0%, SEV: 1.9%; P = 0.347), or pacemaker implantation (BEV: 2.2%, SEV: 1.9%; P = 0.898) were found.
Conclusions: In patients who underwent ViV-TAVR for failed small aortic bioprostheses, those receiving a SEV exhibited a better valve hemodynamic profile at 1-year follow-up. There were no differences between SEV and BEV regarding functional status, quality of life, or clinical outcomes.
Competing Interests: Funding Support and Author Disclosures Dr Nuche is supported by a grant from the Fundación Alfonso Martín Escudero (Madrid, Spain). Dr Rodés-Cabau holds the Research Chair “Fondation Famille Jacques Larivière” for the Development of Structural Heart Disease Interventions (Laval University). Dr Abbas has received research grants and consulting fees from Edwards Lifesciences. Dr Nombela-Franco holds a research grant (INT19/00040 and CM21/00091) from the Spanish Ministry of Science and Innovation (Instituto de Salud Carlos III); and has received consulting fees from Edwards Lifesciences. Dr Conradi is a member of the advisory board of Medtronic, Abbott, JenaValve, and Neovase; and has received consulting fees from Edwards Lifesciences, Boston Scientific, New Valve Technology, and MicroInterventions. Dr Pibarot has received institutional funding from Edwards Lifesciences, Medtronic, Pi-Cardia, Cardiac Success, Roche Diagnostics for echocardiography core laboratory analyses, blood biomarker analyses, and research studies in the field of interventional and pharmacologic treatment of valvular heart diseases, for which he received no personal compensation. Dr Rodés-Cabau has received institutional research grants and consultant/speaker fees from Edwards Lifesciences and Medtronic. All other authors have reported that they have no relationships relevant to the contents of this paper to disclose.
(Copyright © 2023 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.)
Databáze: MEDLINE