Potential exposure to metal fumes, particulates, and organic vapors during radiotherapy shielding block fabrication.

Autor: DeMeyer CL, Whitehead LW, Jacobson AP, Brown DG
Jazyk: angličtina
Zdroj: Medical physics [Med Phys] 1986 Sep-Oct; Vol. 13 (5), pp. 748-50.
DOI: 10.1118/1.595841
Abstrakt: The shielding-block fabrication areas of three hospitals were surveyed to assess inhalation exposure to lead (Pb), cadmium (Cd), bismuth (Bi), and tin (Sn) fumes, as well as styrene and methyl chloride vapors. Area and personal breathing zone samples were collected for various steps in the block fabrication process. Only 3 of 16 air samples for metals resulted in detectable levels of Pb and/or Cd. The levels were well below the Occupational Safety and Health Administration (OSHA) Permissible Exposure Limits, excluding a sample which contained a visible metal fragment. Bi and Sn were not detected in any samples. Methyl chloride and styrene vapors were not detected in any air samples during foam cutting procedures. Total particulates (TP) were measurable in 11 of 17 air samples (ranging from 0.01 to 2.1 mg/m3). TP values were below the OSHA federal standard for nuisance particulates, which is 15 mg/m3. The data suggest that the materials and procedures sampled do not present an inhalation hazard to employees who construct shielding blocks. Precautions should, however, be exercised to prevent exposure under extreme procedural conditions such as soldering or overheating of alloy, and by other means such as ingestion. Care should also be taken during cleanup or housekeeping to prevent re-entrainment into the work atmosphere of mechanically generated metal particles or materials condensed within melting pots (which may be high in metal content).
Databáze: MEDLINE