Tuning polymer-blood and polymer-cytoplasm membrane interactions by manipulating the architecture of poly(2-oxazoline) triblock copolymers.

Autor: Lobaz V; Institute of Macromolecular Chemistry of the Czech Academy of Sciences, Heyrovského n. 1888/2, 162 06 Prague 6, Czechia. Electronic address: lobaz@imc.cas.cz., Liščáková V; Institute of Organic Chemistry and Biochemistry of the Czech Academy of Sciences, Flemingovo n. 542/2, 160 00 Prague 6, Czechia; Laboratory of Theranostics, Institute of Biochemistry and Experimental Oncology, First Faculty of Medicine, U Nemocnice 5, 128 53 Prague 2, Czechia., Sedlák F; Institute of Organic Chemistry and Biochemistry of the Czech Academy of Sciences, Flemingovo n. 542/2, 160 00 Prague 6, Czechia; Laboratory of Theranostics, Institute of Biochemistry and Experimental Oncology, First Faculty of Medicine, U Nemocnice 5, 128 53 Prague 2, Czechia., Musil D; Institute of Organic Chemistry and Biochemistry of the Czech Academy of Sciences, Flemingovo n. 542/2, 160 00 Prague 6, Czechia; Department of Genetics and Microbiology, Faculty of Science, Charles University, Viničná 5, 128 44 Prague 2, Czechia., Petrova SL; Institute of Macromolecular Chemistry of the Czech Academy of Sciences, Heyrovského n. 1888/2, 162 06 Prague 6, Czechia., Šeděnková I; Institute of Macromolecular Chemistry of the Czech Academy of Sciences, Heyrovského n. 1888/2, 162 06 Prague 6, Czechia., Pánek J; Institute of Macromolecular Chemistry of the Czech Academy of Sciences, Heyrovského n. 1888/2, 162 06 Prague 6, Czechia., Kučka J; Institute of Macromolecular Chemistry of the Czech Academy of Sciences, Heyrovského n. 1888/2, 162 06 Prague 6, Czechia., Konefał R; Institute of Macromolecular Chemistry of the Czech Academy of Sciences, Heyrovského n. 1888/2, 162 06 Prague 6, Czechia., Tihlaříková E; Environmental Electron Microscopy Group, Institute of Scientific Instruments of the Czech Academy of Sciences, Královopolská 147, 61 200 Brno, Czechia., Neděla V; Environmental Electron Microscopy Group, Institute of Scientific Instruments of the Czech Academy of Sciences, Královopolská 147, 61 200 Brno, Czechia., Pankrác J; Center for Advanced Preclinical Imaging (CAPI), First Faculty of Medicine, Charles University, Salmovská 3, Prague 2, Czechia., Šefc L; Center for Advanced Preclinical Imaging (CAPI), First Faculty of Medicine, Charles University, Salmovská 3, Prague 2, Czechia., Hrubý M; Institute of Macromolecular Chemistry of the Czech Academy of Sciences, Heyrovského n. 1888/2, 162 06 Prague 6, Czechia., Šácha P; Institute of Organic Chemistry and Biochemistry of the Czech Academy of Sciences, Flemingovo n. 542/2, 160 00 Prague 6, Czechia., Štěpánek P; Institute of Macromolecular Chemistry of the Czech Academy of Sciences, Heyrovského n. 1888/2, 162 06 Prague 6, Czechia.
Jazyk: angličtina
Zdroj: Colloids and surfaces. B, Biointerfaces [Colloids Surf B Biointerfaces] 2023 Nov; Vol. 231, pp. 113564. Date of Electronic Publication: 2023 Sep 21.
DOI: 10.1016/j.colsurfb.2023.113564
Abstrakt: Bioactive moieties designed to bind to cell membrane receptors benefit from coupling with polymeric carriers that have enhanced affinity to the cell membrane. When bound to the cell surface, such carriers create a "2D solution" of a ligand with a significantly increased concentration near a membrane-bound receptor compared to a freely water-soluble ligand. Bifunctional polymeric carriers based on amphiphilic triblock copolymers were synthesized from 2-pent-4-ynyl oxazoline, 2-nonyl oxazoline and 2-ethyl oxazoline. Their self-assembly and interactions with plasma proteins and HEK 293 cells were studied in detail. The affinity of these triblock copolymers to HEK 293 cell membranes and organ tissues was tunable by the overall hydrophobicity of the polymer molecule, which is determined by the length of the hydrophobic and hydrophilic blocks. The circulation time and biodistribution of three representative triblock copolymers were monitored after intravenous administration to C57BL/6 albino mice. A prolonged circulation time was observed for polymers with longer hydrophobic blocks, despite their molecular weight being below the renal threshold.
Competing Interests: Declaration of Competing Interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.
(Copyright © 2023 Elsevier B.V. All rights reserved.)
Databáze: MEDLINE