The effect of water storage on nanoindentation creep of various CAD-CAM composite blocks.
Autor: | Alamoush RA; Department of Fixed and Removable Prosthodontics, School of Dentistry, the University of Jordan, Amman, 11942, Jordan., Salim NA; Department of Fixed and Removable Prosthodontics, School of Dentistry, the University of Jordan, Amman, 11942, Jordan., Elraggal A; Operative Dentistry, Conservative Dentistry Department, Faculty of Dentistry, Alexandria University, Alexandria, Egypt. alaa.elraggal@alexu.edu.eg., Satterthwaite JD; Division Dentistry, School of Medical Sciences, the University of Manchester, Manchester, UK., Silikas N; Division Dentistry, School of Medical Sciences, the University of Manchester, Manchester, UK. |
---|---|
Jazyk: | angličtina |
Zdroj: | BMC oral health [BMC Oral Health] 2023 Aug 07; Vol. 23 (1), pp. 543. Date of Electronic Publication: 2023 Aug 07. |
DOI: | 10.1186/s12903-023-03145-1 |
Abstrakt: | Background: To study the effect of water storage (3 months) on the creep deformation of various CAD-CAM composite structures at the nanoscale and compare it to that at the macroscale. Methods: Seven CAD-CAM blocks were investigated: five resin-composite blocks (RCB), one polymer-infiltrated ceramic network (PICN) block, and one ceramic-filled polyetheretherketone (PEEK) block. Specimens of each material (n = 6) were separated into two groups (n = 3) according to their storage conditions (24 h dry storage at 23˚C and 3 months storage in 37˚C distilled water). Nano-indentation creep measurements were undertaken (creep depth measured in µm) using a nanoindenter (Nanovea) equipped with Berkovich three-sided pyramidal diamond tip. The machine was set for the chosen parameters: a load of 20 gf, a pause of 20 s, and the material type. Thirty indentations on 3 samples were made for each material for each test. Data were analysed using two-way ANOVA followed by one-way ANOVA and Bonferroni post hoc tests and independent t-test (< 0.05) for comparisons between the materials. Results: The nanoindentation creep depth after 24 h storage ranged from 0.09 to 0.33 μm and increased after 3 months storage in distilled water to between 0.28 and 3.46 μm. There was a statistically significant difference in nanoindentation creep behaviour between the two storage conditions for each investigated material (independent t-test) and between all materials (Bonferroni post hoc). There was a non-significant negative correlation between nanoindentation creep (µm) and filler weight% at 24 h dry storage but a significant correlation at 3 months of water storage. A further non-significant positive correlation between nanoindentation creep (µm) and bulk compressive creep (%) was found. Conclusion: The PICN material showed superior dimensional stability in terms of nanoindentation creep depth in both storage conditions. Other composite blocks showed comparable performance at 24 h dry condition, but an increased nanoindentation creep upon water storage. (© 2023. BioMed Central Ltd., part of Springer Nature.) |
Databáze: | MEDLINE |
Externí odkaz: |