The international reference system for beta-particle emitting radionuclides: Validation through the pilot study CCRI(II)-P1.Co-60.
Autor: | Coulon R; Bureau International des Poids et Mesures, Pavillon de Breteuil, F-92312, Sèvres Cedex, France. Electronic address: romain.coulon@bipm.org., Leobino da Silva MA; Laboratório Nacional de Metrologia das Radiações Ionizantes, Instituto de Radioproteção e Dosimetria, LNMRI/IRD, Av. Salvador Allende, 3773, CEP 22783-127, Barra da Tijuca, Rio de Janeiro, RJ, Brazil., Bendall E; National Physical Laboratory, Hampton Road Middlesex, TW11 0LW, Teddington, United Kingdom., Bergeron DE; National Institute of Standards and Technology, 100 Bureau Drive, Gaithersburg, MD, 20899, USA., Bobin C; Université Paris-Saclay, CEA, List, Laboratoire National Henri Becquerel (LNE-LNHB), F-91120, Palaiseau, France., Bonková I; Slovenský Metrologický ústav, Karloveská 63, 842 55, Bratislava, Slovakia., Bowan AHH; Australian Nuclear Science and Technology Organisation, Australia., Ryszard B; National Centre for Nuclear Research Radioisotope Centre POLATOM, 05-400, Otwock, Poland., Capogni M; ENEA-Italian National Institute of Ionizing Radiation Metrology, Via Anguillarese - 301, I-00123, Roma, (IT), Italy., Capone M; ENEA-Italian National Institute of Ionizing Radiation Metrology, Via Anguillarese - 301, I-00123, Roma, (IT), Italy., Carconi P; ENEA-Italian National Institute of Ionizing Radiation Metrology, Via Anguillarese - 301, I-00123, Roma, (IT), Italy., Cassette P; Université Paris-Saclay, CEA, List, Laboratoire National Henri Becquerel (LNE-LNHB), F-91120, Palaiseau, France., Jeffrey TC; National Institute of Standards and Technology, 100 Bureau Drive, Gaithersburg, MD, 20899, USA., Clark EL; Australian Nuclear Science and Technology Organisation, Australia., Collins S; National Physical Laboratory, Hampton Road Middlesex, TW11 0LW, Teddington, United Kingdom., Courte S; Bureau International des Poids et Mesures, Pavillon de Breteuil, F-92312, Sèvres Cedex, France., Czudek M; National Centre for Nuclear Research Radioisotope Centre POLATOM, 05-400, Otwock, Poland., da Silva CJ; Laboratório Nacional de Metrologia das Radiações Ionizantes, Instituto de Radioproteção e Dosimetria, LNMRI/IRD, Av. Salvador Allende, 3773, CEP 22783-127, Barra da Tijuca, Rio de Janeiro, RJ, Brazil., de Almeida Rangel J; Laboratório Nacional de Metrologia das Radiações Ionizantes, Instituto de Radioproteção e Dosimetria, LNMRI/IRD, Av. Salvador Allende, 3773, CEP 22783-127, Barra da Tijuca, Rio de Janeiro, RJ, Brazil., De Felice P; ENEA-Italian National Institute of Ionizing Radiation Metrology, Via Anguillarese - 301, I-00123, Roma, (IT), Italy., Fan F; National Institute of Metrology (NIM), 100029, Beijing, China., Fazio A; ENEA-Italian National Institute of Ionizing Radiation Metrology, Via Anguillarese - 301, I-00123, Roma, (IT), Italy., Fitzgerald RP; National Institute of Standards and Technology, 100 Bureau Drive, Gaithersburg, MD, 20899, USA., Fréchou C; Université Paris-Saclay, CEA, List, Laboratoire National Henri Becquerel (LNE-LNHB), F-91120, Palaiseau, France., Galea R; National Research Council of Canada, 1200 Montreal Road, Ottawa, ON, K1A0R6, Canada., Gressier V; Bureau International des Poids et Mesures, Pavillon de Breteuil, F-92312, Sèvres Cedex, France., Iwahara A; Laboratório Nacional de Metrologia das Radiações Ionizantes, Instituto de Radioproteção e Dosimetria, LNMRI/IRD, Av. Salvador Allende, 3773, CEP 22783-127, Barra da Tijuca, Rio de Janeiro, RJ, Brazil., Judge SM; Bureau International des Poids et Mesures, Pavillon de Breteuil, F-92312, Sèvres Cedex, France., Keevers CMB; Australian Nuclear Science and Technology Organisation, Australia., Keightley J; National Physical Laboratory, Hampton Road Middlesex, TW11 0LW, Teddington, United Kingdom., Kossert K; Physikalisch-Technische Bundesanstalt, Bundesallee 100, 38116, Braunschweig, Germany., Krivošík M; Slovenský Metrologický ústav, Karloveská 63, 842 55, Bratislava, Slovakia., Kulkarni DB; Bhabha Atomic Research Centre, Mumbai, India., Laureano-Perez L; National Institute of Standards and Technology, 100 Bureau Drive, Gaithersburg, MD, 20899, USA., Lech E; National Centre for Nuclear Research Radioisotope Centre POLATOM, 05-400, Otwock, Poland., Leiras A; Laboratório Nacional de Metrologia das Radiações Ionizantes, Instituto de Radioproteção e Dosimetria, LNMRI/IRD, Av. Salvador Allende, 3773, CEP 22783-127, Barra da Tijuca, Rio de Janeiro, RJ, Brazil., Liang J; National Institute of Metrology (NIM), 100029, Beijing, China., Lima da Cruz PA; Laboratório Nacional de Metrologia das Radiações Ionizantes, Instituto de Radioproteção e Dosimetria, LNMRI/IRD, Av. Salvador Allende, 3773, CEP 22783-127, Barra da Tijuca, Rio de Janeiro, RJ, Brazil., Lins da Silva R; Laboratório Nacional de Metrologia das Radiações Ionizantes, Instituto de Radioproteção e Dosimetria, LNMRI/IRD, Av. Salvador Allende, 3773, CEP 22783-127, Barra da Tijuca, Rio de Janeiro, RJ, Brazil., Listkowska A; National Centre for Nuclear Research Radioisotope Centre POLATOM, 05-400, Otwock, Poland., Liu H; National Institute of Metrology (NIM), 100029, Beijing, China., Liu M; National Institute of Metrology (NIM), 100029, Beijing, China., Lubbe J; National Metrology Institute of South Africa, 15 Lower Hope Road, Rosebank, Cape Town, 7700, South Africa., Michotte C; Bureau International des Poids et Mesures, Pavillon de Breteuil, F-92312, Sèvres Cedex, France., Moore K; National Research Council of Canada, 1200 Montreal Road, Ottawa, ON, K1A0R6, Canada., Nähle O; Physikalisch-Technische Bundesanstalt, Bundesallee 100, 38116, Braunschweig, Germany., Nonis M; Bureau International des Poids et Mesures, Pavillon de Breteuil, F-92312, Sèvres Cedex, France., Pearce A; National Physical Laboratory, Hampton Road Middlesex, TW11 0LW, Teddington, United Kingdom., Pibida L; National Institute of Standards and Technology, 100 Bureau Drive, Gaithersburg, MD, 20899, USA., Quadros ALL; Laboratório Nacional de Metrologia das Radiações Ionizantes, Instituto de Radioproteção e Dosimetria, LNMRI/IRD, Av. Salvador Allende, 3773, CEP 22783-127, Barra da Tijuca, Rio de Janeiro, RJ, Brazil., Ramirez N; National Physical Laboratory, Hampton Road Middlesex, TW11 0LW, Teddington, United Kingdom., Ravindra A; Bhabha Atomic Research Centre, Mumbai, India., Sabot B; Université Paris-Saclay, CEA, List, Laboratoire National Henri Becquerel (LNE-LNHB), F-91120, Palaiseau, France., Saganowski P; National Centre for Nuclear Research Radioisotope Centre POLATOM, 05-400, Otwock, Poland., Sathian V; Bhabha Atomic Research Centre, Mumbai, India., Smith ML; Australian Nuclear Science and Technology Organisation, Australia., Sharma R; Bhabha Atomic Research Centre, Mumbai, India., Takács MP; Physikalisch-Technische Bundesanstalt, Bundesallee 100, 38116, Braunschweig, Germany., van Rooy MW; National Metrology Institute of South Africa, 15 Lower Hope Road, Rosebank, Cape Town, 7700, South Africa., Shearman R; National Physical Laboratory, Hampton Road Middlesex, TW11 0LW, Teddington, United Kingdom., van Staden MJ; National Metrology Institute of South Africa, 15 Lower Hope Road, Rosebank, Cape Town, 7700, South Africa., van Wyngaardt WM; Australian Nuclear Science and Technology Organisation, Australia., Yang Z; National Institute of Metrology (NIM), 100029, Beijing, China., Zarifi M; Australian Nuclear Science and Technology Organisation, Australia., Zhang M; National Institute of Metrology (NIM), 100029, Beijing, China., Ziemek T; National Centre for Nuclear Research Radioisotope Centre POLATOM, 05-400, Otwock, Poland. |
---|---|
Jazyk: | angličtina |
Zdroj: | Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine [Appl Radiat Isot] 2023 Oct; Vol. 200, pp. 110945. Date of Electronic Publication: 2023 Jul 26. |
DOI: | 10.1016/j.apradiso.2023.110945 |
Abstrakt: | The Bureau International des Poids et Mesures (BIPM) is developing a new transfer instrument to extend its centralized services for assessing the international equivalence of radioactive standards to new radionuclides. A liquid scintillation counter using the triple/double coincidence ratio method is being studied and tested in the CCRI(II)-P1.Co-60 pilot study. The pilot study, involving 13 participating laboratories with primary calibration capabilities, validated the approach against the original international reference system based on ionization chambers, which has been in operation since 1976. The results are in agreement and an accuracy suitable for purpose, below 5×10 -4 , is achieved. The pilot study also reveals an issue when impurities emitting low-energy electrons are present in the standard solution, which have a different impact on liquid scintillation counting compared to other primary measurement methods. Competing Interests: Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper. (Copyright © 2023 Elsevier Ltd. All rights reserved.) |
Databáze: | MEDLINE |
Externí odkaz: |