Fabrication and Applications of Potentiometric Membrane Sensors Based on Specific Recognition Sites for the Measurement of the Quinolone Antibacterial Drug Gemifloxacin.

Autor: Mostafa GAE; Department of Pharmaceutical Chemistry, College of Pharmacy, King Saud University, P.O. Box 2457, Riyadh 11451, Saudi Arabia., Ali EA; Department of Pharmaceutical Chemistry, College of Pharmacy, King Saud University, P.O. Box 2457, Riyadh 11451, Saudi Arabia., Alsalahi RA; Department of Pharmaceutical Chemistry, College of Pharmacy, King Saud University, P.O. Box 2457, Riyadh 11451, Saudi Arabia., Alrabiah H; Department of Pharmaceutical Chemistry, College of Pharmacy, King Saud University, P.O. Box 2457, Riyadh 11451, Saudi Arabia.
Jazyk: angličtina
Zdroj: Molecules (Basel, Switzerland) [Molecules] 2023 Jun 30; Vol. 28 (13). Date of Electronic Publication: 2023 Jun 30.
DOI: 10.3390/molecules28135144
Abstrakt: Supramolecular gemifloxacin (GF) sensors have been developed. Supramolecular chemistry is primarily concerned with noncovalent intermolecular and intramolecular interactions, which are far weaker than covalent connections, but they can be exploited to develop sensors with remarkable affinity for a target analyte. In order to determine the dose form of the quinolone antibacterial drug gemifloxacin, the current study's goal is to adapt three polyvinylchloride (PVC) membrane sensors into an electrochemical technique. Three new potentiometric membrane sensors with cylindric form and responsive to gemifloxacin (GF) were developed. The sensors' setup is based on the usage of o-nitrophenyl octyl ether (o-NPOE) as a plasticizer in a PVC matrix, β-cyclodextrin (β-CD) (sensor 1), γ-cyclodextrin (γ-CD) (sensor 2), and 4-tert-butylcalix[8]arene (calixarene) (sensor 3) as an ionophore, potassium tetrakis (4-chlorophenyl) borate (KTpClPB) as an ion additive for determination of GF. The developed method was verified according to IUPAC guidelines. The sensors under examination have good selectivity for GF, according to their selectivity coefficients. The constructed sensors demonstrated a significant response towards to GF over a concentration range of 2.4 × 10 -6 , 2.7 × 10 -6 , and 2.42 × 10 -6 mol L -1 for sensors 1, 2, and 3, respectively. The sensors showed near-Nernstian cationic response for GF at 55 mV, 56 mV, and 60 mV per decade for sensors 1, 2, and 3, respectively. Good recovery and relative standard deviations during the day and between days are displayed by the sensors. They demonstrated good stability, quick response times, long lives, rapid recovery, and precision while also exhibiting good selectivity for GF in various matrices. To determine GF in bulk and dose form, the developed sensors have been successfully deployed. The sensors were also employed as end-point indicators for titrating GF with sodium tetraphenyl borate.
Databáze: MEDLINE
Nepřihlášeným uživatelům se plný text nezobrazuje