Long-term outcomes of CPAP-treated sleep apnea patients: Impact of blood-pressure responses after CPAP initiation and of treatment adherence.
Autor: | Bocoum AM; HP2 (Hypoxia and Physio-Pathologies) Laboratory, Inserm (French National Institute of Health and Medical Research) U1300, University Grenoble Alpes, Grenoble, France; EFCR (Cardiovascular and Respiratory Function) Laboratory, Grenoble Alpes University Hospital, Grenoble, France., Bailly S; HP2 (Hypoxia and Physio-Pathologies) Laboratory, Inserm (French National Institute of Health and Medical Research) U1300, University Grenoble Alpes, Grenoble, France; EFCR (Cardiovascular and Respiratory Function) Laboratory, Grenoble Alpes University Hospital, Grenoble, France., Joyeux-Faure M; HP2 (Hypoxia and Physio-Pathologies) Laboratory, Inserm (French National Institute of Health and Medical Research) U1300, University Grenoble Alpes, Grenoble, France; EFCR (Cardiovascular and Respiratory Function) Laboratory, Grenoble Alpes University Hospital, Grenoble, France., Baillieul S; HP2 (Hypoxia and Physio-Pathologies) Laboratory, Inserm (French National Institute of Health and Medical Research) U1300, University Grenoble Alpes, Grenoble, France; EFCR (Cardiovascular and Respiratory Function) Laboratory, Grenoble Alpes University Hospital, Grenoble, France., Arbib F; HP2 (Hypoxia and Physio-Pathologies) Laboratory, Inserm (French National Institute of Health and Medical Research) U1300, University Grenoble Alpes, Grenoble, France; EFCR (Cardiovascular and Respiratory Function) Laboratory, Grenoble Alpes University Hospital, Grenoble, France., Kang CL; HP2 (Hypoxia and Physio-Pathologies) Laboratory, Inserm (French National Institute of Health and Medical Research) U1300, University Grenoble Alpes, Grenoble, France; EFCR (Cardiovascular and Respiratory Function) Laboratory, Grenoble Alpes University Hospital, Grenoble, France., Ngo V; HP2 (Hypoxia and Physio-Pathologies) Laboratory, Inserm (French National Institute of Health and Medical Research) U1300, University Grenoble Alpes, Grenoble, France; EFCR (Cardiovascular and Respiratory Function) Laboratory, Grenoble Alpes University Hospital, Grenoble, France., Boutouyrie P; Inserm (French National Institute of Health and Medical Research) U970, Hôpital Européen Georges Pompidou, Assistance Publique Hôpitaux de Paris, Paris, France; Université de Paris, Paris, France., Tamisier R; HP2 (Hypoxia and Physio-Pathologies) Laboratory, Inserm (French National Institute of Health and Medical Research) U1300, University Grenoble Alpes, Grenoble, France; EFCR (Cardiovascular and Respiratory Function) Laboratory, Grenoble Alpes University Hospital, Grenoble, France., Pépin JL; HP2 (Hypoxia and Physio-Pathologies) Laboratory, Inserm (French National Institute of Health and Medical Research) U1300, University Grenoble Alpes, Grenoble, France; EFCR (Cardiovascular and Respiratory Function) Laboratory, Grenoble Alpes University Hospital, Grenoble, France. Electronic address: JPepin@chu-grenoble.fr. |
---|---|
Jazyk: | angličtina |
Zdroj: | Sleep medicine [Sleep Med] 2023 Sep; Vol. 109, pp. 25-31. Date of Electronic Publication: 2023 Jun 28. |
DOI: | 10.1016/j.sleep.2023.06.022 |
Abstrakt: | Background and Objective: In randomized controlled trials, continuous positive airway pressure (CPAP) is reported as lowering blood pressure (BP) with a mean systolic blood pressure effect size of 2.5 mmHg. These trials have a median follow-up of less than 6 months. Whether this initial BP response during the first months of CPAP treatment translates into a reduction in long-term cardiovascular events and mortality is unknown. Methods: This observational study addressed long-term hard cardiovascular outcomes and all-cause mortality in a well-defined population of 241 patients previously included in the AgirSASadom parallel randomized controlled trial (assessing whether fixed-pressure CPAP was superior to auto-adjusted CPAP in reducing BP (baseline evaluations 2010-2012)). Long-term outcomes were analyzed using a Cox survival model, and a logistic regression analysis was performed for long-term CPAP adherence. Results: Sixty-nine cardiovascular events occurred in 61 patients during a median follow-up of 113 months (interquartile range [102 ; 124]) giving an incidence of 26 for 1000 person-years. Twenty-one (8.7%) patients died. BP values at baseline (i.e., office and 24-h BP) was a strong predictor of incident cardiometabolic events and mortality (p < 0.01) whereas initial BP response after the first four months of CPAP was not related to outcomes. Long-term CPAP adherence above 4 h/night was associated with a reduction in all-cause mortality (Log-rank P = 0.02) but not in the occurrence of long-term cardiovascular events. Conclusion: Independently of initial blood pressure response, long-term CPAP adherence is one of the prerequisites for reducing mortality. Competing Interests: Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper. (Copyright © 2023 Elsevier B.V. All rights reserved.) |
Databáze: | MEDLINE |
Externí odkaz: |