Evaluation of a New Method of Leukocyte Extractions from the Leukoreduction Filter.

Autor: Malati ZA; Blood Transfusion Research Center, High Institute for Research and Education in Transfusion Medicine, Tehran, Iran., Pourfathollah AA; Blood Transfusion Research Center, High Institute for Research and Education in Transfusion Medicine, Tehran, Iran.; Immunology Department Faculty Medical Science, Tarbiat Modares University, Tehran, Iran., Dabbaghi R; Ophthalmic Research Center, Research Institute for Ophthalmology and Vision Science, Shahid Beheshti University of Medical Sciences, Tehran, Iran., Balagholi S; Blood Transfusion Research Center, High Institute for Research and Education in Transfusion Medicine, Tehran, Iran.; Ophthalmic Research Center, Research Institute for Ophthalmology and Vision Science, Shahid Beheshti University of Medical Sciences, Tehran, Iran., Javan MR; Blood Transfusion Research Center, High Institute for Research and Education in Transfusion Medicine, Tehran, Iran.
Jazyk: angličtina
Zdroj: Indian journal of hematology & blood transfusion : an official journal of Indian Society of Hematology and Blood Transfusion [Indian J Hematol Blood Transfus] 2023 Jul; Vol. 39 (3), pp. 478-486. Date of Electronic Publication: 2023 Jan 13.
DOI: 10.1007/s12288-022-01618-x
Abstrakt: This study's purpose was to optimize the leukocyte extraction protocol and evaluate the efficacy of this new protocol. 12BioR blood filters were collected from Tehran Blood Transfusion Center. A twosyringe system and Multi-step rinsing were designed for cell extraction. The final purpose of this optimization was: (1) removed the residual RBCs, (2) reversed the leukocyte trapping process, and (3) remove the microparticles to obtain the high yield of target cells. Finally, Extracted cells were evaluated by Automated Cell count; Samples smear differential cell count, Trypan blue, and Annexin-PI staining. The results showed that on average 11.88 × 10 8  ± 3.32 leukocytes recovered after indirect washing and that the mean count of granulocytes, lymphocytes, and Monocyte in this sample was 5.24 ± 2.18 × 10 8 , 5.57 ± 1.74 × 10 8 , and 0.56 ± 0.38 × 10 8 respectively. Also, the mean percent of manual differential cell count after concentration was 42.81%, 41.80%, and 15.82% for granulocytes, lymphocytes, and monocytes respectively. Moreover, viability and apoptosis assay showed > 95% viability in mononuclear cells recovered from LRFs. It is concluded that the use of a double-syringe system and RBC and microparticles removal from leukoreduction filters lead to acceptable viable leukocyte count that can be used in in vitro and in vivo studies.
Competing Interests: Conflict of interestThe authors declare that they have no conflict of interest.
(© The Author(s), under exclusive licence to Indian Society of Hematology and Blood Transfusion 2022. Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.)