The international normalised ratio to monitor coagulation factor production during normothermic machine perfusion of human donor livers.
Autor: | van den Boom BP; Surgical Research Laboratory and Section of Hepatobiliary Surgery and Liver Transplantation, Department of Surgery, University of Groningen, University Medical Center Groningen, Groningen, the Netherlands., Bodewes SB; Surgical Research Laboratory and Section of Hepatobiliary Surgery and Liver Transplantation, Department of Surgery, University of Groningen, University Medical Center Groningen, Groningen, the Netherlands., Lascaris B; Surgical Research Laboratory and Section of Hepatobiliary Surgery and Liver Transplantation, Department of Surgery, University of Groningen, University Medical Center Groningen, Groningen, the Netherlands., Adelmeijer J; Surgical Research Laboratory and Section of Hepatobiliary Surgery and Liver Transplantation, Department of Surgery, University of Groningen, University Medical Center Groningen, Groningen, the Netherlands., Porte RJ; Section of HPB Surgery and Liver Transplantation, Department of Surgery, University of Groningen, University Medical Center Groningen, Groningen, the Netherlands., de Meijer VE; Section of HPB Surgery and Liver Transplantation, Department of Surgery, University of Groningen, University Medical Center Groningen, Groningen, the Netherlands., Lisman T; Surgical Research Laboratory and Section of Hepatobiliary Surgery and Liver Transplantation, Department of Surgery, University of Groningen, University Medical Center Groningen, Groningen, the Netherlands; Section of HPB Surgery and Liver Transplantation, Department of Surgery, University of Groningen, University Medical Center Groningen, Groningen, the Netherlands. Electronic address: j.a.lisman@umcg.nl. |
---|---|
Jazyk: | angličtina |
Zdroj: | Thrombosis research [Thromb Res] 2023 Aug; Vol. 228, pp. 64-71. Date of Electronic Publication: 2023 Jun 01. |
DOI: | 10.1016/j.thromres.2023.05.025 |
Abstrakt: | Background: Normothermic machine perfusion (NMP) of donor livers allows for new diagnostic and therapeutic strategies. As the liver produces most of the haemostatic proteins, coagulation assays such as the International Normalised Ratio (INR) performed in perfusate may be useful to assess hepatocellular function of donor livers undergoing NMP. However, high concentrations of heparin and low levels of fibrinogen may affect coagulation assays. Methods: Thirty donor livers that underwent NMP were retrospectively included in this study, of which 18 were subsequently transplanted. We measured INRs in perfusate in presence or absence of exogenously added fibrinogen and/or polybrene. Additionally, we prospectively included 14 donor livers that underwent NMP (of which 11 were transplanted) and measured INR using both a laboratory coagulation analyser and a point-of-care device. Results: In untreated perfusate samples, the INR was above the detection limit in all donor livers. Addition of both fibrinogen and polybrene was required for adequate INR assessment. INRs decreased over time and detectable perfusate INR values were found in 17/18 donor livers at the end of NMP. INR results were similar between the coagulation analyser and the point-of-care device, but did not correlate with established hepatocellular viability criteria. Conclusions: Most of the donor livers that were transplanted showed a detectable perfusate INR at the end of NMP, but samples require processing to allow for INR measurements using laboratory coagulation analysers. Point-of-care devices bypass this need for processing. The INR does not correlate with established viability criteria and might therefore have additional predictive value. Competing Interests: Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper. (Copyright © 2023 The Authors. Published by Elsevier Ltd.. All rights reserved.) |
Databáze: | MEDLINE |
Externí odkaz: |