Risk of malignancy in T1-hyperintense Bosniak version 2019 class II and IIF cystic renal masses.
Autor: | Shen L; Department of Radiology, Stanford University School of Medicine, 300 Pasteur Drive, Stanford, CA, 94305, USA. lyshen@stanford.edu., Tse JR; Department of Radiology, Stanford University School of Medicine, 300 Pasteur Drive, Stanford, CA, 94305, USA., Lemieux S; Department of Radiology, Stanford University School of Medicine, 300 Pasteur Drive, Stanford, CA, 94305, USA., Yoon L; Department of Radiology, Stanford University School of Medicine, 300 Pasteur Drive, Stanford, CA, 94305, USA., Mullane PC; Department of Pathology, Stanford University School of Medicine, Lane Building, L235, 300 Pasteur Drive, Stanford, CA, 94305, USA., Liang T; Department of Radiology, Stanford University School of Medicine, 300 Pasteur Drive, Stanford, CA, 94305, USA., Davenport MS; Department of Radiology and Urology, Michigan Medicine, University of Michigan, 1500 E Medical Center Dr, Ann Arbor, MI, B2-A209A48109, USA., Pedrosa I; Department of Radiology, University of Texas Southwestern Medical Center, 2201 Inwood Rd. 2nd Floor, Suite 202, Dallas, TX, 75390, USA., Silverman SG; Department of Radiology, Brigham and Women's Hospital, Harvard University, 75 Francis St., Boston, MA, 02115, USA. |
---|---|
Jazyk: | angličtina |
Zdroj: | Abdominal radiology (New York) [Abdom Radiol (NY)] 2023 Aug; Vol. 48 (8), pp. 2636-2648. Date of Electronic Publication: 2023 May 18. |
DOI: | 10.1007/s00261-023-03955-5 |
Abstrakt: | Background: Bosniak classification version 2019 includes cystic masses in class II and IIF based partly on their hyperintense appearance at T1-weighted MRI. The prevalence of malignancy in non-enhancing heterogeneously T1-hyperintense masses is unknown, nor whether the pattern of T1 hyperintensity affects malignancy likelihood. Purpose: To determine the malignancy proportion among six patterns of T1 hyperintensity within non-enhancing cystic renal masses. Methods: This retrospective, single-institution study included 72 Bosniak class II and IIF, non-enhancing, T1-hyperintense cystic renal masses. Diagnosis was confirmed by histopathology or by follow-up imaging demonstrating 5-year size and morphologic stability, decreased in size by ≥ 30%, resolution, or Bosniak down-classification. Six patterns of T1 hyperintensity were pre-defined: homogeneous (pattern A), fluid-fluid level (pattern B), peripherally markedly T1-hyperintense (pattern C), containing a T1-hyperintense non-enhancing nodule (pattern D), peripherally T1-hypointense (pattern E), and heterogeneously T1-hyperintense without a distinct pattern (pattern F). Three readers independently assigned each mass to a pattern. Individual and mean malignancy proportion were determined. Mann-Whitney test and Fischer's exact test compared the likelihood of malignancy between patterns. Inter-reader agreement was analyzed with Gwet's agreement coefficient (AC). Results: Among 72 masses, the mean number of masses assigned was 11 (15%) to pattern A, 21 (29%) to pattern B, 6 (8%) to pattern C, 7 (10%) to pattern D, 5 (7%) to pattern E, and 22 (31%) to pattern F. Five of 72 masses (7%) were malignant; none was assigned pattern A, B, or D. Mean malignancy proportion was 5% (0/9, 1/6, and 0/4) for pattern C, 13% (0/4, 1/3, and 1/7) for pattern E, and 18% (5/20, 3/21, and 4/25) for pattern F. Malignant masses were more likely assigned to pattern E or F (p = 0.003-0.039). Inter-reader agreement was substantial (Gwet's AC: 0.68). Conclusion: Bosniak version 2019 class IIF masses that are non-enhancing and heterogeneously T1-hyperintense with a fluid-fluid level are likely benign. Those that are non-enhancing and heterogeneously T1-hyperintense without a distinct pattern have a malignancy proportion up to 25% (5/20). (© 2023. The Author(s), under exclusive licence to Springer Science+Business Media, LLC, part of Springer Nature.) |
Databáze: | MEDLINE |
Externí odkaz: |