Influence of Denture Cleansers on the Retention Loss of Attachment Systems Retained Implant Overdenture.

Autor: AlRumaih HS; Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam 31441, Saudi Arabia., Albarrak AA; Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam 31441, Saudi Arabia., AlMedaires M; Department of Restorative Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam 31441, Saudi Arabia., Alsulaiman AA; Department of Preventive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam 31441, Saudi Arabia., Baba NZ; Advanced Dental Education Program in Implant Dentistry, Loma Linda University, School of Dentistry, Loma Linda, CL, USA., Alshahrani FA; Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam 31441, Saudi Arabia., Alqarawi FK; Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam 31441, Saudi Arabia., Al-Dulaijan YA; Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam 31441, Saudi Arabia., Alzoubi F; Department of General Dental Practice, Faculty of Dentistry, Kuwait University, P.O. Box 24923, Safat 13110, Kuwait., Alhumaidan AA; Department of Preventive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam 31441, Saudi Arabia., Gad MM; Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam 31441, Saudi Arabia.
Jazyk: angličtina
Zdroj: International journal of biomaterials [Int J Biomater] 2023 Apr 29; Vol. 2023, pp. 5077785. Date of Electronic Publication: 2023 Apr 29 (Print Publication: 2023).
DOI: 10.1155/2023/5077785
Abstrakt: Background: This study aimed to evaluate the effects of different denture cleansing solutions (DCSs) on the retention of Locator and Locator R-Tx attachment systems of implant retained overdentures (IRO).
Methods: Two part acrylic resin blocks were fabricated, upper part contained metal housing and plastic inserts and lower part contained implant analogs and abutments. Eighty pink plastic inserts (40/attachment, 10/solution) were immersed in Corega, Fittydent, sodium hypochlorite, and water for a time simulating upto 1-year of clinical usage. Acrylic blocks were held on a universal testing machine for a pull-out test to record the dislodgement force. Measurements were conducted after 6 months (T1) and 12 months (T2). One-way ANOVA followed by Tukey's HSD test was used to analyze the results ( α  = 0.05).
Results: For both attachments, retention significantly decreased after immersion in different solutions at T2 ( P < 0.001). Locator R-Tx attachment in NaOCl showed a significant decrease in retention compared with other solutions at T1. At T2, there was a significant decrease in retention for all DCS compared with water ( P < 0.001). Locator R-TX showed higher retention values per solution compared to Locator attachment ( P < 0.001). In terms of retention loss %, NaOCl recorded the highest (61.87%) loss, followed by Corega (55.54%) and Fittydent (43.13%), whereas water demonstrated the best retention (16.13%) in both groups.
Conclusion: Locator R-TX has better retention with different DCS immersion. The loss of retention varied with different types of DCS and NaOCl recorded the highest retention loss. Therefore, denture cleanser selection must be guided by the type of IRO attachment.
Competing Interests: The authors declare that they have no conflicts of interest.
(Copyright © 2023 Hamad S. AlRumaih et al.)
Databáze: MEDLINE
Nepřihlášeným uživatelům se plný text nezobrazuje