Ultra-high resolution CT imaging of interstitial lung disease: impact of photon-counting CT in 112 patients.

Autor: Gaillandre Y; ULR 2694 METRICS Evaluation des technologies de santé et des pratiques médicales, F-59000, Lille, France., Duhamel A; ULR 2694 METRICS Evaluation des technologies de santé et des pratiques médicales, F-59000, Lille, France.; Department of Biostatistics, ULR 2694 METRICS Evaluation des technologies de santé et des pratiques médicales, Univ. Lille, CHU Lille, F-59000, Lille, France., Flohr T; Department of Computed Tomography Research & Development, Siemens Healthineers, 91301, Forchheim, Germany., Faivre JB; ULR 2694 METRICS Evaluation des technologies de santé et des pratiques médicales, F-59000, Lille, France., Khung S; ULR 2694 METRICS Evaluation des technologies de santé et des pratiques médicales, F-59000, Lille, France., Hutt A; ULR 2694 METRICS Evaluation des technologies de santé et des pratiques médicales, F-59000, Lille, France., Felloni P; ULR 2694 METRICS Evaluation des technologies de santé et des pratiques médicales, F-59000, Lille, France., Remy J; ULR 2694 METRICS Evaluation des technologies de santé et des pratiques médicales, F-59000, Lille, France., Remy-Jardin M; ULR 2694 METRICS Evaluation des technologies de santé et des pratiques médicales, F-59000, Lille, France. martine.remy@chu-lille.fr.; Department of Thoracic Imaging, Heart & Lung Institute, University Hospital Center of Lille, Blvd Jules Leclercq, 59000, Lille, France. martine.remy@chu-lille.fr.
Jazyk: angličtina
Zdroj: European radiology [Eur Radiol] 2023 Aug; Vol. 33 (8), pp. 5528-5539. Date of Electronic Publication: 2023 Apr 18.
DOI: 10.1007/s00330-023-09616-x
Abstrakt: Objectives: To compare lung parenchyma analysis on ultra-high resolution (UHR) images of a photon-counting CT (PCCT) scanner with that of high-resolution (HR) images of an energy-integrating detector CT (EID-CT).
Methods: A total of 112 patients with stable interstitial lung disease (ILD) were investigated (a) at T0 with HRCT on a 3 rd -generation dual-source CT scanner; (b) at T1 with UHR on a PCCT scanner; (c) with a comparison of 1-mm-thick lung images.
Results: Despite a higher level of objective noise at T1 (74.1 ± 14.1 UH vs 38.1 ± 8.7 UH; p < 0.0001), higher qualitative scores were observed at T1 with (a) visualization of more distal bronchial divisions (median order; Q1-Q3) (T1: 10 th division [9-10]; T0: 9 th division [8-9]; p < 0.0001); (b) greater scores of sharpness of bronchial walls (p < 0.0001) and right major fissure (p < 0.0001). The scores of visualization of CT features of ILD were significantly superior at T1 (micronodules: p = 0.03; linear opacities, intralobular reticulation, bronchiectasis, bronchiolectasis, and honeycombing: p < 0.0001), leading to the reclassification of 4 patients with non-fibrotic ILD at T0, recognized with fibrotic ILD at T1. At T1, the mean (± SD) radiation dose (CTDI vol : 2.7 ± 0.5 mGy; DLP: 88.5 ± 21 mGy.cm) was significantly lower than that delivered at T0 (CTDI vol : 3.6 ± 0.9 mGy; DLP: 129.8 ± 31.7 mGy.cm) (p < 0.0001), corresponding to a mean reduction of 27% and 32% for the CTDI vol and DLP, respectively.
Conclusions: The UHR scanning mode of PCCT allowed a more precise depiction of CT features of ILDs and reclassification of ILD patterns with significant radiation dose reduction.
Clinical Relevance Statement: Evaluation of lung parenchymal structures with ultra-high-resolution makes subtle changes at the level of the secondary pulmonary lobules and lung microcirculation becoming visually accessible, opening new options for synergistic collaborations between highly-detailed morphology and artificial intelligence.
Key Points: • Photon-counting CT (PCCT) provides a more precise analysis of lung parenchymal structures and CT features of interstitial lung diseases (ILDs). • The UHR mode ensures a more precise delineation of fine fibrotic abnormalities with the potential of modifying the categorization of ILD patterns. • Better image quality at a lower radiation dose with PCCT opens new horizons for further dose reduction in noncontrast UHR examinations.
(© 2023. The Author(s), under exclusive licence to European Society of Radiology.)
Databáze: MEDLINE