Technical Pitfalls for Fenestrated-Branched Endovascular Aortic Repair Following PETTICOAT.
Autor: | Baghbani-Oskouei A; Advanced Aortic Research Program, Department of Cardiothoracic and Vascular Surgery, McGovern Medical School, University of Texas Health Science Center at Houston, Houston, TX, USA., Tenorio ER; Advanced Aortic Research Program, Department of Cardiothoracic and Vascular Surgery, McGovern Medical School, University of Texas Health Science Center at Houston, Houston, TX, USA., Dias-Neto M; Advanced Aortic Research Program, Department of Cardiothoracic and Vascular Surgery, McGovern Medical School, University of Texas Health Science Center at Houston, Houston, TX, USA., Vacirca A; Advanced Aortic Research Program, Department of Cardiothoracic and Vascular Surgery, McGovern Medical School, University of Texas Health Science Center at Houston, Houston, TX, USA., Mirza AK; Advanced Aortic Research Program, Department of Cardiothoracic and Vascular Surgery, McGovern Medical School, University of Texas Health Science Center at Houston, Houston, TX, USA., Saqib N; Advanced Aortic Research Program, Department of Cardiothoracic and Vascular Surgery, McGovern Medical School, University of Texas Health Science Center at Houston, Houston, TX, USA., Mendes BC; Division of Vascular and Endovascular Surgery, Mayo Clinic, Rochester, MN, USA., Ocasio L; Department of Diagnostic and Interventional Imaging, McGovern Medical School, University of Texas Health Science Center at Houston, Houston, TX, USA., Macedo TA; Department of Diagnostic and Interventional Imaging, McGovern Medical School, University of Texas Health Science Center at Houston, Houston, TX, USA., Oderich GS; Advanced Aortic Research Program, Department of Cardiothoracic and Vascular Surgery, McGovern Medical School, University of Texas Health Science Center at Houston, Houston, TX, USA. |
---|---|
Jazyk: | angličtina |
Zdroj: | Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists [J Endovasc Ther] 2024 Oct; Vol. 31 (5), pp. 790-796. Date of Electronic Publication: 2023 Mar 30. |
DOI: | 10.1177/15266028231163439 |
Abstrakt: | Purpose: The Provisional Extension to Induce Complete Attachment Technique (PETTICOAT) uses a bare-metal stent to scaffold the true lumen in patients with acute or subacute aortic dissections. While it is designed to facilitate remodeling, some patients with chronic post-dissection thoracoabdominal aortic aneurysms (TAAAs) require repair. This study describes the technical pitfalls of fenestrated-branched endovascular aortic repair (FB-EVAR) in patients who underwent prior PETTICOAT repair. Technique: We report 3 patients with extent II TAAAs who had prior bare-metal dissection stents treated by FB-EVAR. Two patients required maneuvers to reroute the aortic guidewire, which was initially placed in-between stent struts. This was recognized before the deployment of the fenestrated-branched device. A third patient had difficult advancement of the celiac bridging stent due to a conflict of the tip of the stent delivery system into one of the stent struts, requiring to redo catheterization and pre-stenting with a balloon-expandable stent. There were no mortalities and target-related events after a follow-up of 12 to 27 months. Conclusion: FB-EVAR following the PETTICOAT is infrequent, but technical difficulties should be recognized to prevent complications from the inadvertent deployment of the fenestrated-branched stent-graft component in-between stent struts. Clinical Impact: The present study highlights a few maneuvers to prevent or overcome possible complications during endovascular repair of chronic post-dissection thoracoabdominal aortic aneurysm following PETTICOAT. The main problem to be recognized is the placement of the aortic wire beyond one of the struts of the existing bare-metal stent. Moreover, encroachment of catheters or the bridging stent delivery system into the stent struts may potentially cause difficulties. Competing Interests: Declaration of Conflicting InterestsThe author(s) declared no potential conflicts of interest with respect to the research, authorship, and/or publication of this article. |
Databáze: | MEDLINE |
Externí odkaz: |