A Case of Abnormal Results Caused by Urine Contamination in Serum During Detection.
Autor: | Zhang L, Wang E, Lu M, Ling Y |
---|---|
Jazyk: | angličtina |
Zdroj: | Clinical laboratory [Clin Lab] 2023 Mar 01; Vol. 69 (3). |
DOI: | 10.7754/Clin.Lab.2022.220608 |
Abstrakt: | Background: Unqualified samples directly affect the accuracy of test results in clinical laboratory. Timely and accurate identification of unqualified specimens can avoid the occurrence of medical adverse events. Methods: This study reported a case of abnormal results caused by urine carrying contamination in serum during detection. Results: During the testing process, improper operation of laboratory staff led to serum contamination with urine, which affected the accuracy of the test results. Conclusions: In addition to the pre-inspection stage, all laboratories should also pay attention to the quality control of sample during the inspection, so as to ensure the accuracy of the results and medical safety. |
Databáze: | MEDLINE |
Externí odkaz: |