A comparative study between 10-MHz and 15-MHz ultrasound probes for retinal evaluation in silicone-oil-filled globes.
Autor: | Albadawi MA; Department of Ophthalmology, Faculty of Medicine, Kasr Al Ainy School of Medicine, Cairo University, Cairo, Egypt., Allam RSHM; Department of Ophthalmology, Faculty of Medicine, Kasr Al Ainy School of Medicine, Cairo University, Cairo, Egypt. ryham_allam@cu.edu.eg., Khalil NMM; Department of Ophthalmology, Faculty of Medicine, Kasr Al Ainy School of Medicine, Cairo University, Cairo, Egypt., Eissa IM; Department of Ophthalmology, Faculty of Medicine, Kasr Al Ainy School of Medicine, Cairo University, Cairo, Egypt. |
---|---|
Jazyk: | angličtina |
Zdroj: | Eye (London, England) [Eye (Lond)] 2023 Oct; Vol. 37 (14), pp. 3020-3025. Date of Electronic Publication: 2023 Mar 06. |
DOI: | 10.1038/s41433-023-02464-5 |
Abstrakt: | Purpose: To compare 10-MHz and 15-MHz B-scan probes regarding the detection and localization of retinal detachment (RD) in silicone-oil-filled eyes. Methods: This cross-sectional observational study included 100 eyes (98 patients) -having media opacity precluding fundus examination- scheduled for silicone-oil removal. Patients were examined in the sitting-position using both frequencies one week preoperatively. Longitudinal and transverse scans were taken in primary-gaze, inferior, inferonasal, and inferotemporal positions to detect the presence/absence and extent of RD. Patients were sub-grouped according to axial lengths (AXLs), state of silicone emulsification, and globe filling. Agreement between sonographic and intraoperative observations was compared. Results: No statistically significant differences were found between 15-MHz and intra-operative findings regarding RD detection (P = 0.752) and accurate localization of inferior, inferonasal, and inferotemporal RD (P = 0.279, 0.606, and 0.599). There were statistically significant differences between 10-MHz and intra-operative findings regarding RD detection and localization (P < 0.001). The 15-MHz probe was superior to 10-MHz probe regarding the accuracy of RD detection and localization (94% and 47%, respectively). The accuracy of 15-MHz probe was 88%, 83%, and 85% in detecting and localizing inferior, inferonasal, and inferotemporal RD compared to 45%, 60%, and 62% with 10-MHz probe. The 15-MHz probe showed better sensitivity while 10-MHz probe showed better accuracy in eyes with short AXLs. The 10-MHz probe showed better sensitivity in patients with sonographic emulsification while15-MHz probe had better sensitivity in detecting vitreoretinal-interface disorders. Conclusion: The 15-MHz B-scan probe is more accurate in detecting and localizing recurrent RD in silicone-oil-filled globes with higher sensitivity in detecting vitreoretinal-interface disorders. (© 2023. The Author(s).) |
Databáze: | MEDLINE |
Externí odkaz: |