Autor: Pytak RA 3rd; Michigan State University Veterinary Medical Center, East Lansing, Michigan, USA., Pirie CG; Michigan State University Veterinary Medical Center, East Lansing, Michigan, USA., Harman CD; Michigan State University Veterinary Medical Center, East Lansing, Michigan, USA., Anderson AL; Michigan State University Veterinary Medical Center, East Lansing, Michigan, USA., Yao SX; Michigan State University Veterinary Medical Center, East Lansing, Michigan, USA., Komáromy AM; Michigan State University Veterinary Medical Center, East Lansing, Michigan, USA.
Jazyk: angličtina
Zdroj: Veterinary ophthalmology [Vet Ophthalmol] 2023 Nov; Vol. 26 (6), pp. 514-523. Date of Electronic Publication: 2023 Feb 28.
DOI: 10.1111/vop.13075
Abstrakt: Objective: To evaluate anterior segment angiographic findings in hypertensive ADAMTS10-open-angle glaucoma (ADAMTS10-OAG) eyes as compared to normotensive control eyes.
Animals Studied: Nine ADAMTS10-OAG beagles and four wild-type control dogs.
Procedures: Anterior segment angiography was performed under general anesthesia following intravenous injection of indocyanine green (ICG; 1 mg/kg) and sodium fluorescein (SF; 20 mg/kg) using a Heidelberg Spectralis® confocal scanning laser ophthalmoscope. Time to onset of iridal angiographic phases and the presence/severity of dye leakage into the iris stromal and/or aqueous humor were recorded. Group findings were compared, and multiple linear regression analysis was performed to identify potential factor associations with disease status.
Results: Time to onset of all angiographic phases visualized using ICG was significantly prolonged while time to onset of SF leakage into the aqueous humor was significantly reduced in glaucomatous eyes compared to controls. Only glaucomatous eyes (n = 9) demonstrated evidence of SF stromal leakage. Mean intraocular pressure (IOP) and age were significantly higher, while mean cardiac pulse was significantly lower in glaucomatous eyes compared to controls. Blood pressure and ocular perfusion pressure were not significantly different between groups. Multiple linear regression analysis, controlling for age, IOP, and pulse demonstrated glaucoma, was not predictive of the time to onset of any angiographic phase, stromal, or aqueous humor leakage. However, pulse was a significant factor contributing to the severity of aqueous humor leakage.
Conclusions: A compromised vascular supply to the anterior segment exists in dogs with ADAMTS10-OAG. These observations warrant further exploration of what role altered perfusion and/or disruption to the blood-aqueous barrier may play.