Spectrum bias in algorithms derived by artificial intelligence: a case study in detecting aortic stenosis using electrocardiograms.

Autor: Tseng AS; Department of Cardiovascular Medicine, Mayo Clinic, 200 First Street Southwest, Rochester, MN 55905, USA., Shelly-Cohen M; Department of Cardiovascular Medicine, Mayo Clinic, 200 First Street Southwest, Rochester, MN 55905, USA., Attia IZ; Department of Cardiovascular Medicine, Mayo Clinic, 200 First Street Southwest, Rochester, MN 55905, USA., Noseworthy PA; Department of Cardiovascular Medicine, Mayo Clinic, 200 First Street Southwest, Rochester, MN 55905, USA., Friedman PA; Department of Cardiovascular Medicine, Mayo Clinic, 200 First Street Southwest, Rochester, MN 55905, USA., Oh JK; Department of Cardiovascular Medicine, Mayo Clinic, 200 First Street Southwest, Rochester, MN 55905, USA., Lopez-Jimenez F; Department of Cardiovascular Medicine, Mayo Clinic, 200 First Street Southwest, Rochester, MN 55905, USA.
Jazyk: angličtina
Zdroj: European heart journal. Digital health [Eur Heart J Digit Health] 2021 Jul 14; Vol. 2 (4), pp. 561-567. Date of Electronic Publication: 2021 Jul 14 (Print Publication: 2021).
DOI: 10.1093/ehjdh/ztab061
Abstrakt: Aims: Spectrum bias can arise when a diagnostic test is derived from study populations with different disease spectra than the target population, resulting in poor generalizability. We used a real-world artificial intelligence (AI)-derived algorithm to detect severe aortic stenosis (AS) to experimentally assess the effect of spectrum bias on test performance.
Methods and Results: All adult patients at the Mayo Clinic between 1 January 1989 and 30 September 2019 with transthoracic echocardiograms within 180 days after electrocardiogram (ECG) were identified. Two models were developed from two distinct patient cohorts: a whole-spectrum cohort comparing severe AS to any non-severe AS and an extreme-spectrum cohort comparing severe AS to no AS at all. Model performance was assessed. Overall, 258 607 patients had valid ECG and echocardiograms pairs. The area under the receiver operator curve was 0.87 and 0.91 for the whole-spectrum and extreme-spectrum models, respectively. Sensitivity and specificity for the whole-spectrum model was 80% and 81%, respectively, while for the extreme-spectrum model it was 84% and 84%, respectively. When applying the AI-ECG derived from the extreme-spectrum cohort to patients in the whole-spectrum cohort, the sensitivity, specificity, and area under the curve dropped to 83%, 73%, and 0.86, respectively.
Conclusion: While the algorithm performed robustly in identifying severe AS, this study shows that limiting datasets to clearly positive or negative labels leads to overestimation of test performance when testing an AI algorithm in the setting of classifying severe AS using ECG data. While the effect of the bias may be modest in this example, clinicians should be aware of the existence of such a bias in AI-derived algorithms.
(© The Author(s) 2021. Published by Oxford University Press on behalf of the European Society of Cardiology.)
Databáze: MEDLINE