New Analytical Methods for the Determination of New Anti-Viral Drug Favipiravir: A Potential Therapeutic Drug Against Covid-19 Virus, in Bulk and Dosage Forms.

Autor: Itigimatha N; Department of Chemistry, MS Ramaiah Institute of Technology, Bangalore, 560054 India.; Affiliated to Visvesvaraya Technological University, Belagavi, Karnataka 590018 India., Chadchan KS; Department of Chemistry, BLDEA's V. P. Dr. P. G. Halakatti College of Engineering and Technology, Vijayapur, Karnataka 586103 India., Yallur BC; Department of Chemistry, MS Ramaiah Institute of Technology, Bangalore, 560054 India.; Affiliated to Visvesvaraya Technological University, Belagavi, Karnataka 590018 India., Hadagali MD; Department of Studies in Chemistry, Davangere University, Shivagangothri, Davangere, Karnataka 577002 India.
Jazyk: angličtina
Zdroj: Pharmaceutical chemistry journal [Pharm Chem J] 2023; Vol. 56 (10), pp. 1419-1425. Date of Electronic Publication: 2023 Jan 12.
DOI: 10.1007/s11094-023-02807-2
Abstrakt: Simple, accurate and robust analytical methods have been developed and validated for the determination of favipiravir (FVPR) by RP-HPLC and UV spectroscopy techniques as per the ICH guidelines. In the RP-HPLC method for FVPR determination, the mobile phase was ammonium acetate buffer pH 6.5 in pump Aand methanol in pump B. The C18 (Sunfire) 5 μm, 4.6 × 250 mm column was used as a stationary phase, and the detection wavelength was at 323 nm. Under these conditions, FVPR was eluted as a sharp peak at 2.65 min and the overall time taken for each injection was 10 min. In case of the UV spectroscopy method, standard FVPR solutions were prepared with pure ethanol and scanned from 250 to 400 nm and a flourishing spectrum was obtained at 323 nm. Hence, the wavelength of 323 nm was fixed for the whole process of validation in both techniques. The limit of detection (LOD) and limit of quantification (LOQ) in the RP-HPLC method were 1.0 and 3.5 μg/mL, respectively, and the linearity was established in the 10 to 50 μg/mL range. In the UV spectroscopy method, the LOD and LOQ values were found to be 3.5 and 12 μg/mL, respectively, and the linearity was established within 20 to 60 μg/mL range. The regression coefficient was found to exceed 0.999 in both methods. The proposed RP-HPLC and UV spectroscopy techniques are simple, accurate, rugged and robust.
(© Springer Science+Business Media, LLC, part of Springer Nature 2023, Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.)
Databáze: MEDLINE
Nepřihlášeným uživatelům se plný text nezobrazuje