Evaporative water loss from dairy cows in climate-controlled respiration chambers.
Autor: | Zhou M; Farm Technology Group, Wageningen University and Research, 6700 AH Wageningen, the Netherlands., Groot Koerkamp PWG; Farm Technology Group, Wageningen University and Research, 6700 AH Wageningen, the Netherlands., Huynh TTT; Farm Technology Group, Wageningen University and Research, 6700 AH Wageningen, the Netherlands., Aarnink AJA; Farm Technology Group, Wageningen University and Research, 6700 AH Wageningen, the Netherlands; Wageningen Livestock Research, Wageningen University and Research, 6708 WD Wageningen, the Netherlands. Electronic address: andre.aarnink@wur.nl. |
---|---|
Jazyk: | angličtina |
Zdroj: | Journal of dairy science [J Dairy Sci] 2023 Mar; Vol. 106 (3), pp. 2035-2043. Date of Electronic Publication: 2023 Jan 09. |
DOI: | 10.3168/jds.2022-22489 |
Abstrakt: | The effects of ambient temperature (AT) on total evaporative water loss from dairy cows at different relative humidity (RH) and air velocity (AV) levels were studied. Twenty Holstein dairy cows with an average parity of 2.0 ± 0.7 and body weight of 687 ± 46 kg participated in the study. Two climate-controlled respiration chambers were used. The experimental indoor climate was programmed to follow a diurnal pattern with AT at night being 9°C lower than during the day. Night AT was gradually increased from 7 to 21°C and day AT was increased from 16°C to 30°C within an 8-d period, both with an incremental change of 2°C/d. The effect of 3 RH levels with a diurnal pattern were studied as well, with low values during the day and high values during the night: low (day, 30%; night, 50%), medium (day, 45%; night, 70%), and high (day, 60%; night, 90%). The effects of AV were studied during the daytime at 3 levels: no fan (0.1 m/s), fan at medium speed (1.0 m/s), and fan at high speed (1.5 m/s). The medium and high AV levels were only combined with medium RH. In total, there were 5 treatments with 4 replicates each. The animals had free access to feed and water. Based on the water balance principle inside the respiration chambers, the total evaporative water loss from dairy cows at a daily level was quantified by measuring the mass of water in the incoming and outgoing air, condensed water, added water from a humidifier, and evaporative water from a wet floor, drinking bowl, manure reservoir, and water bucket. Water evaporation from a sample skin area was measured with a ventilated skin box, and water evaporation, through respiration with a face mask. The results show that RH/AV levels had no significant effect on total evaporative water loss, whereas the interaction effect between RH/AV with AT was significant. Cows at a high RH had a tendency for a lower increasing rate of evaporative water loss compared with cows at a low RH (0.61 vs. 0.79 kg/d per 1°C increase of AT). Cows at medium and high AV levels had a greater increasing rate than cows at low AV (0.91 and 0.95 vs. 0.71 kg/d per 1°C increase of AT, respectively). The increase of evaporative heat loss from dairy cows was mainly a result of the increase in evaporation (of sweat) from the skin. The skin water evaporation determined with the water balance method (less evaporation from respiration) and the ventilated skin box method showed no significant difference. The implication of this study is that cows at a high AT depend mainly on evaporative cooling from the skin. The ventilated skin box method, measuring only a small part of the skin during a short period during the day, can be a convenient and accurate way to determine the total cutaneous evaporative water loss from cows. (The Authors. Published by Elsevier Inc. and Fass Inc. on behalf of the American Dairy Science Association®. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).) |
Databáze: | MEDLINE |
Externí odkaz: |