Biomechanical Comparison of Asymmetric Implant Configurations for All-on-Four Treatment Using Three-Dimensional Finite Element Analysis.

Autor: Gönül O; Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Marmara University, 34722 İstanbul, Turkey., Çicek A; Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Marmara University, 34722 İstanbul, Turkey., Afat İM; Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Marmara University, 34722 İstanbul, Turkey., Akdoğan ET; Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, İstanbul Kent University, 34433 İstanbul, Turkey., Atalı O; Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Marmara University, 34722 İstanbul, Turkey.
Jazyk: angličtina
Zdroj: Life (Basel, Switzerland) [Life (Basel)] 2022 Nov 23; Vol. 12 (12). Date of Electronic Publication: 2022 Nov 23.
DOI: 10.3390/life12121963
Abstrakt: The aim of this study is to examine the effect of unilaterally more posterior placement of implants (Straumann BLT 4.1 mm in diameter and 12 mm long) applied according to the all-on-four concept on the stress distribution on bone, implants, and other prosthetic components, using the finite element analysis method. Three scenarios were modelled: For Model 1 (M1), anterior implants were placed symmetrically perpendicular to the bone in the right and left lateral incisor region, while the necks of the posterior implants placed symmetrically in the second premolar region were angled at 30 degrees. For Model 2 (M2) the implant in the left second premolar region was placed to the first molar region unilaterally. For Model 3 (M3) the implant in the left lateral incisor region was placed to the canine region unilaterally. Vertical and oblique forces (100 N) were applied in the right first molar region. The von Mises and maximum (Pmax) and minimum (Pmin) principal stresses were obtained. The highest stress concentration on the cortical bone was observed in the second premolar region in all models when oblique forces were applied. M1 was highest (8.992 MPa) followed closely by M3 (8.780 MPa) and M2 was lowest (3.692 MPa). The highest stress concentration on the prosthetic parts was observed in this framework when oblique forces were applied. M2 was highest (621.43 MPa) followed by M3 (409.16 MPa) and the lowest was M1 (309.43 MPa). It is thought that placing the implant further posterior to first molar region may prevent the bone resorption that occurs with high stress around the crestal bone. However, increased stress on the implants and prosthetic parts may lead to failures.
Databáze: MEDLINE
Nepřihlášeným uživatelům se plný text nezobrazuje