Successful retrieval of a needle point from the breast through a vacuum-assisted breast biopsy system.
Autor: | Sibilio A; UOC - Chirurgia Senologica Forlì-Ravenna, Ravenna (RA), Italy., Bucchi E; Centro di Prevenzione Oncologica, Lugo (RA), Italy., Alfieri C; Centro di Prevenzione Oncologica, Lugo (RA), Italy., Marongiu F; UOC - Chirurgia Senologica Forlì-Ravenna, Ravenna (RA), Italy., Curcio A; UOC - Chirurgia Senologica Forlì-Ravenna, Ravenna (RA), Italy. |
---|---|
Jazyk: | angličtina |
Zdroj: | Acta radiologica open [Acta Radiol Open] 2022 Dec 06; Vol. 11 (12), pp. 20584601221143499. Date of Electronic Publication: 2022 Dec 06 (Print Publication: 2022). |
DOI: | 10.1177/20584601221143499 |
Abstrakt: | Stereotactic vacuum-assisted breast biopsy (VABB) system is generally used to perform breast biopsies after identifying suspicious lesions that are occult on ultrasound. In this case, we used an 8-Gauge VABB to retrieve a needle point retained in the outer-lower quadrant of the right breast of a patient previously treated with lumpectomy. The use of stereotactic VABB system in this specific clinical setting has been never described before and resulted minimally invasive and perfectly suitable for correct localisation and retrieval of the 3-mm needle point; moreover, it may be easily reproduced elsewhere. Competing Interests: The author(s) declared the following potential conflicts of interest with respect to the research, authorship, and/or publication of this article: The Authors declare that there is no conflict of interest. (© The Author(s) 2022.) |
Databáze: | MEDLINE |