Point-of-care electrochemical sensor for selective determination of date rape drug "ketamine" based on core-shell molecularly imprinted polymer.
Autor: | Soliman SS; Analytical Chemistry Department, Faculty of Pharmacy, October 6 University, October 6 City, Giza, 12858, Egypt., Mahmoud AM; Analytical Chemistry Department, Faculty of Pharmacy, Cairo University, El-Kasr-El Aini Street, Cairo, 11562, Egypt., Elghobashy MR; Analytical Chemistry Department, Faculty of Pharmacy, October 6 University, October 6 City, Giza, 12858, Egypt; Analytical Chemistry Department, Faculty of Pharmacy, Cairo University, El-Kasr-El Aini Street, Cairo, 11562, Egypt., Zaazaa HE; Analytical Chemistry Department, Faculty of Pharmacy, Cairo University, El-Kasr-El Aini Street, Cairo, 11562, Egypt., Sedik GA; Analytical Chemistry Department, Faculty of Pharmacy, Cairo University, El-Kasr-El Aini Street, Cairo, 11562, Egypt. Electronic address: ghada.sedik@pharma.cu.edu.eg. |
---|---|
Jazyk: | angličtina |
Zdroj: | Talanta [Talanta] 2023 Mar 01; Vol. 254, pp. 124151. Date of Electronic Publication: 2022 Nov 29. |
DOI: | 10.1016/j.talanta.2022.124151 |
Abstrakt: | Misuse of illicit drugs is a serious problem that became the primary concern for many authorities worldwide. Point-of-care (POC) diagnostic tools can provide accurate and fast screening information that helps to detect illicit drugs in a short time. A portable, disposable and reproducible core-shell molecularly imprinted polymer (MIP) screen-printed sensor was synthesized as a POC analyzer for the assay of the date rape drug "ketamine hydrochloride" in different matrices. Firstly, the screen-printed electrode substrate was modified electrochemically with polyaniline (PANI) as an ion-to-electron transducer interlayer to improve the potential signal stability. Secondly, core-shell MIP was prepared, the core consisting of silica nanoparticles prepared by Stober's method, while the MIP shell was synthesized onto silica nanoparticles surface by copolymerizing methacrylic acid functional monomer and the crossing agent; ethylene glycol dimethacrylate in the presence of ketamine as a template molecule. Finally, the core-shell MIP was incorporated into the PVC membrane as an ionophore and drop-casted over PANI modified screen-printed carbon electrode. The imprinting process and the morphology of MIP were examined using scanning electron microscopy, Fourier-transform infrared and X-ray photoelectron spectroscopic methods. The sensor exhibited a short response time within 3-5 s in a pH range (2.0-5.0). The potential profile indicated a linear relationship in a dynamic concentration range of 1.0 × 10 -6 M to 1.0 × 10 -2 M with a slope of 54.7 mV/decade. The sensor was employed to determine ketamine in biological matrices and beverages. Competing Interests: Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper. (Copyright © 2022 Elsevier B.V. All rights reserved.) |
Databáze: | MEDLINE |
Externí odkaz: |