Quantifying Aerosol Generation in Maxillofacial Trauma Repair Techniques.

Autor: McCann A; Department of Otolaryngology - Head and Neck Surgery, College of Medicine, University of Cincinnati, Cincinnati, OH, USA., Singerman K; Department of Otolaryngology - Head and Neck Surgery, College of Medicine, University of Cincinnati, Cincinnati, OH, USA., Coxe J; Department of Otolaryngology - Head and Neck Surgery, College of Medicine, University of Cincinnati, Cincinnati, OH, USA., Singletary J; Department of Environmental and Public Health Sciences, College of Medicine, University of Cincinnati, Cincinnati, OH, USA., Wang J; Department of Environmental and Public Health Sciences, College of Medicine, University of Cincinnati, Cincinnati, OH, USA., Collar R; Department of Otolaryngology - Head and Neck Surgery, College of Medicine, University of Cincinnati, Cincinnati, OH, USA., Hsieh TY; Department of Otolaryngology - Head and Neck Surgery, College of Medicine, University of Cincinnati, Cincinnati, OH, USA.
Jazyk: angličtina
Zdroj: Craniomaxillofacial trauma & reconstruction [Craniomaxillofac Trauma Reconstr] 2022 Dec; Vol. 15 (4), pp. 362-368. Date of Electronic Publication: 2021 Dec 29.
DOI: 10.1177/19433875211059314
Abstrakt: Study Design: Cadaveric simulation study.
Objective: The novel coronavirus (COVID-19), which can be transmitted via aerosolized viral particles, has directed focus on protection of healthcare workers during procedures involving the upper aerodigestive tract, including maxillofacial trauma repair. This study evaluates particle generation at different distances from open reduction and internal fixation (ORIF) of maxillofacial injuries in the intraoperative setting to reduce the risk of contracting airborne diseases such as COVID-19.
Methods: Two cadaveric specimens in a simulated operating room underwent ORIF of midface and mandible fractures via intraoral incisions as well as maxillomandibular fixation (MMF) using hybrid arch bars. ORIF was performed with both self-drilling screws and with the use of a power drill for creating guide holes. Real-time aerosol concentration was measured throughout each procedure using 3 particle counters placed 0.45, 1.68, and 3.81 m (1.5, 5.5, and 12.5 feet, respectively) from the operative site.
Results: There was a significant decrease in particle concentration in all procedures at 1.68 m compared to 0.45 m, but only 2 of the 5 procedures showed further significant decrease in particle concentration when going from 1.68 to 3.81 m from the operative site. There was significantly less particle concentration generated at all distances when using self-drilling techniques compared to power drilling for ORIF.
Conclusions: Consideration of using self-drilling screwing techniques as well as maintaining physical distancing protocols may decrease risk of transmission of airborne diseases such as COVID-19 while in the intraoperative setting.
Competing Interests: The authors have no disclosures.
(© The Author(s) 2021.)
Databáze: MEDLINE