Sensitive and selective simultaneous biosensing of nandrolone and testosterone as two anabolic steroids by a novel biosensor assisted by second-order calibration.

Autor: Jalalvand AR; Research Center of Oils and Fats, Research Institute for Health Technology, Kermanshah University of Medical Sciences, Kermanshah, Iran. Electronic address: ali.jalalvand1984@gmail.com., Rashidi Z; Faculty of Chemical, Petroleum and Gas Engineering, Semnan University, Semnan, Iran., Khajenoori M; Faculty of Chemical, Petroleum and Gas Engineering, Semnan University, Semnan, Iran.
Jazyk: angličtina
Zdroj: Steroids [Steroids] 2023 Jan; Vol. 189, pp. 109138. Date of Electronic Publication: 2022 Nov 13.
DOI: 10.1016/j.steroids.2022.109138
Abstrakt: Recently, our research group have focused on an interesting project in which a novel dual template molecularly imprinted (DTMIP) biosensor was fabricated and assisted by second-order differential pulse voltammetric (DPV) data for simultaneous determination of nandrolone decanoate (ND) and testosterone decanoate (TS). An indium tin oxide (ITO) was modified with multiwalled carbon nanotubes-graphene-ionic liquid (MWCNT-Gr-IL) and then, the fullerene C 60 was casted onto the surface of MWCNT-Gr-IL/ITO and electrochemically reduced. Finally, DTMIPs were electrosynthesized by electropolymerization of 4-aminobenzoic acid (ABA) as monomer with ND and TS as template molecules to obtain the final structure of the biosensor (DTMIP/C 60 /MWCNT-Gr-IL/ITO). Structure of the biosensor was electrochemically and microscopically characterized. The ND and TS generated two severely overlapped DPVs at the surface of the biosensor which forced us to assist the biosensor with three-way calibration by second-order DPV data to simultaneous determine them. Two second-order algorithms including multivariate curve resolution alternating least squares (MCR-ALS) and parallel factor analysis2 (PARAFAC2) were used to build second-order calibration models and evaluation of their performance in the analysis of synthetic samples showed more superiority of the MCR-ALS than PARAFC2 which motivated us to select PARAFC2 for the analysis of urine samples as real cases. Application of the biosensor assisted by PARAFC2 for the analysis of urine samples towards simultaneous determination of ND and TS was successful.
Competing Interests: Declaration of Competing Interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.
(Copyright © 2022 Elsevier Inc. All rights reserved.)
Databáze: MEDLINE