A Pilot Study on Monomer and Bisphenol A (BPA) Release from UDMA-Based and Conventional Indirect Veneering Composites.

Autor: Hampe T; Department of Prosthodontics, University Medical Center Göttingen, 37075 Göttingen, Germany., Liersch J; Department of Prosthodontics, University Medical Center Göttingen, 37075 Göttingen, Germany., Wiechens B; Department of Prosthodontics, University Medical Center Göttingen, 37075 Göttingen, Germany.; Department of Orthodontics, University Medical Center Göttingen, 37075 Göttingen, Germany., Wassmann T; Department of Prosthodontics, University Medical Center Göttingen, 37075 Göttingen, Germany., Schubert A; Department of Prosthodontics, University Medical Center Göttingen, 37075 Göttingen, Germany., Alhussein M; Molecular Phytopathology and Mycotoxin Research, University of Göttingen, 37077 Göttingen, Germany., Bürgers R; Department of Prosthodontics, University Medical Center Göttingen, 37075 Göttingen, Germany., Krohn S; Department of Prosthodontics, University Medical Center Göttingen, 37075 Göttingen, Germany.; Department of Orthodontics, University Hospital Regensburg, 93053 Regensburg, Germany.
Jazyk: angličtina
Zdroj: Polymers [Polymers (Basel)] 2022 Oct 28; Vol. 14 (21). Date of Electronic Publication: 2022 Oct 28.
DOI: 10.3390/polym14214580
Abstrakt: This study aimed to investigate the release of common monomers from conventional (Dialog Vario, Enamel Plus HFO) and UDMA-based indirect veneering composites (VITA VM LC, GC Gradia). Ten cylindrical samples of each material were prepared ( n = 40), immersed in HPLC grade water, and incubated for 24 h in an incubation shaker at 37 °C and 112 rpm. Extraction was performed following ISO 10993-12 and monomers were detected and quantified by HPLC-MS/MS. In all the samples, urethane dimethacrylate (UDMA) and bisphenol A (BPA) were quantifiable. Compared to water blanks, BPA levels were only elevated in the eluates from conventional composites. In all other samples, concentrations were in the range of extraneous BPA and were therefore clinically irrelevant. Low concentrations of Bisphenol A-glycidyl methacrylate (BisGMA) were found in one BPA-free composite and in both conventional materials. Statistical analyses showed that BPA-free materials released significantly less BisGMA and no BPA, while UDMA elution was comparable to elution from conventional materials. All measured concentrations were below reported effective cytotoxic concentrations. Considering these results, the substitution of BPA-derivatives with UDMA might be beneficial since BPA-associated adverse effects are ruled out. Further studies should be enrolled to test the biocompatibility of UDMA on cells of the oral environment.
Databáze: MEDLINE
Nepřihlášeným uživatelům se plný text nezobrazuje