Stentectomy of a Balloon-Mounted Stent From Vertebrobasilar Circulation: A Technical Report and Literature Review.

Autor: Chakravarthi S; Department of Neurology, Life Neuro Vascular Institute, Guntur, IND., Pasya SKR; Department of Neurology, Life Neuro Vascular Institute, Guntur, IND., Gorijala VK; Department of Neurology, Life Neuro Vascular Institute, Guntur, IND., Guntamukkala A; Department of Neurology, Life Neuro Vascular Institute, Guntur, IND., Sajja KC; Department of Endovascular Neurosurgery, Thomas Jefferson University, Philadelphia, USA.
Jazyk: angličtina
Zdroj: Cureus [Cureus] 2022 Sep 08; Vol. 14 (9), pp. e28956. Date of Electronic Publication: 2022 Sep 08 (Print Publication: 2022).
DOI: 10.7759/cureus.28956
Abstrakt: Stents are being widely used in the neuroendovascular field more often for assisted coiling of aneurysms and treatment of atherosclerotic stenosis. Stent detachment and embolization are one of the most feared complications associated with poor clinical outcomes. Many techniques have been detailed in the literature for extracting such dislodged stents. We describe a case of retrieval of an inadvertently detached balloon-mounted stent from the intracranial left vertebral artery. This occurred in a 58-year-old male patient with a history of diabetes mellitus whose stenting procedure was planned for severe intracranial atherosclerotic disease of bilateral vertebral arteries causing recurrent posterior circulation ischemic events. Stentectomy was performed successfully using a stent retriever. Intracranial vertebral artery stenting was eventually accomplished with excellent clinical outcomes.
Competing Interests: The authors have declared that no competing interests exist.
(Copyright © 2022, Chakravarthi et al.)
Databáze: MEDLINE