3M™ Petrifilm™ Rapid Yeast and Mold Count Plate Method for the Enumeration of Yeast and Mold on Selected Surfaces: AOAC Official Method 2014.05.

Autor: Lingle CK; 3M Company, Food Safety Department, St. Paul, MN 55144-1000, USA., Schumacher AJ; 3M Company, Food Safety Department, St. Paul, MN 55144-1000, USA., Rosauer ML; 3M Company, Food Safety Department, St. Paul, MN 55144-1000, USA., Silbernagel KM; 3M Company, Food Safety Department, St. Paul, MN 55144-1000, USA., Blackburn J; Q Laboratories, Cincinnati, OH 45204, USA.
Jazyk: angličtina
Zdroj: Journal of AOAC International [J AOAC Int] 2023 Mar 01; Vol. 106 (2), pp. 389-400.
DOI: 10.1093/jaoacint/qsac118
Abstrakt: Background: The 3M™ Petrifilm™ Rapid Yeast and Mold Count (RYM) Plate contains nutrients supplemented with antibiotics, a cold-water-soluble gelling agent, and an indicator system that facilitates yeast and mold enumeration in 48-60 h.
Objective: The objective of this study is to evaluate the 3M Petrifilm RYM Plate in a matrix extension study for the enumeration of yeast and mold on stainless steel, sealed concrete, and rubber surfaces.
Methods: The 3M Petrifilm RYM Plate was compared to the U.S. Food and Drug Administration Bacteriological Analytical Manual, Ch. 18: Yeasts, Molds and Mycotoxins in a paired matrix study for enumeration of yeast and mold on stainless steel, sealed concrete, and rubber environmental surfaces.
Results: The 3M Petrifilm RYM Plate demonstrated equivalent performance to the reference method for enumeration of yeast and mold from stainless steel, sealed concrete, and rubber environmental surfaces. There were no significant statistical differences between the 3M Petrifilm RYM Plate and reference method results for the three matrixes evaluated.
Conclusion: The 3M Petrifilm RYM Plate is an effective plating method for enumerating yeast and mold when analyzing stainless steel, sealed concrete, and rubber surfaces.
Highlights: The 3M Petrifilm RYM Plate method allows the user to obtain accurate results within 48-60 h in the matrices evaluated for the presence of yeast and mold when incubated at 25 ± 1°C or 28 ± 1°C. Interpretation and colony counting was straightforward and the 3M Petrifilm RYM Plate method required no additional agar or Petri dishes, creating an easier workflow by cutting down on supplies, sample plating time, and most noticeably, occupying less space in the incubator.
(© The Author(s) 2022. Published by Oxford University Press on behalf of AOAC INTERNATIONAL.)
Databáze: MEDLINE