Effect of C-Clamp Application on Hemodynamic Instability in Polytrauma Victims with Pelvic Fracture.

Autor: Gewiess J; Department of Orthopaedic Surgery and Traumatology, Inselspital, Bern University Hospital, University of Bern, 3010 Bern, Switzerland., Luedi MM; Department of Anaesthesiology and Pain Medicine, Inselspital, Bern University Hospital, University of Bern, 3010 Bern, Switzerland., Schnüriger B; Department of Visceral Surgery and Medicine, Acute Care Surgery Team, Inselspital, Bern University Hospital, University of Bern, 3010 Bern, Switzerland., Tosounidis TH; Department of Orthopaedic Surgery, University Hospital Heraklion Crete, 71500 Heraklion, Crete, Greece., Keel MJB; Department of Orthopaedic Surgery and Traumatology, Inselspital, Bern University Hospital, University of Bern, 3010 Bern, Switzerland., Bastian JD; Department of Orthopaedic Surgery and Traumatology, Inselspital, Bern University Hospital, University of Bern, 3010 Bern, Switzerland.
Jazyk: angličtina
Zdroj: Medicina (Kaunas, Lithuania) [Medicina (Kaunas)] 2022 Sep 16; Vol. 58 (9). Date of Electronic Publication: 2022 Sep 16.
DOI: 10.3390/medicina58091291
Abstrakt: Background and Objectives: C-clamp application may reduce mortality in patients with unstable pelvic fractures and hemodynamic instability. Decreasing C-clamp use over the past decades may have resulted from concerns about its effectiveness and safety. The purpose of this study was to document effective hemodynamic stabilization after C-clamp application by means of vital parameters (primary outcome parameter), and the subsequent effect on metabolic indices and volume management (secondary outcome parameters). Materials and Methods: C-clamp application was performed between 2014 and 2021 for n = 13 patients (50 ± 18 years) with unstable pelvic fractures and hemodynamic instability. Vital parameters, metabolic indices, volume management, and the correlation of factors and potential changes were analyzed. Results: After C-clamp application, increases were measured in systolic blood pressure (+15 mmHg; p = 0.0284) and mean arterial pressure (+12 mmHg; p = 0.0157), and a reduction of volume requirements (p = 0.0266) and bolus vasoactive medication needs (p = 0.0081) were observed. The earlier C-clamp application was performed, the greater the effect (p < 0.05; r > 0.6). Heart rate, shock index, and end-tidal CO2 were not significantly altered. The extent of base deficit, hemoglobin, and lactate did not correlate with changes in vital parameters. Conclusions: In the majority of hemodynamically unstable trauma patients not responding to initial fluid resuscitation and severe pelvic fracture, early C-clamp application had an additive effect on hemodynamic stabilization and reduction in volume substitution. Based on these findings, there is still a rationale for considering early C-clamp stabilization in this group of severely injured patients.
Databáze: MEDLINE