Triple immunochromatographic test system for detection of priority aquatic toxins in water and fish.

Autor: Zvereva EA; Bach Institute of Biochemistry, Research Center of Biotechnology of the Russian Academy of Sciences, Leninsky prospect 33, 119071, Moscow, Russia., Hendrickson OD; Bach Institute of Biochemistry, Research Center of Biotechnology of the Russian Academy of Sciences, Leninsky prospect 33, 119071, Moscow, Russia., Solopova ON; Blokhin National Medical Research Center of Oncology, Ministry of Health of the Russian Federation, Kashirskoye shosse 24, 115478, Moscow, Russia., Zherdev AV; Bach Institute of Biochemistry, Research Center of Biotechnology of the Russian Academy of Sciences, Leninsky prospect 33, 119071, Moscow, Russia., Sveshnikov PG; Russian Research Center for Molecular Diagnostics and Therapy, Sympheropolsky Blvrd., 8, 117638, Moscow, Russia., Dzantiev BB; Bach Institute of Biochemistry, Research Center of Biotechnology of the Russian Academy of Sciences, Leninsky prospect 33, 119071, Moscow, Russia. dzantiev@inbi.ras.ru.
Jazyk: angličtina
Zdroj: Analytical and bioanalytical chemistry [Anal Bioanal Chem] 2022 Nov; Vol. 414 (26), pp. 7553-7563. Date of Electronic Publication: 2022 Sep 13.
DOI: 10.1007/s00216-022-04298-8
Abstrakt: Aquatic toxins are a group of toxic compounds produced by several types of freshwater and marine algae and cyanobacteria and transported through the food chains of water bodies. Potential contamination of aquaculture products (raw and processed fish and seafood) with aquatic toxins requires the use of efficient screening methods for their control. In this study, a multiplex immunochromatographic test system for the simultaneous detection of three aquatic toxins-phycotoxins domoic acid (DA) and okadaic acid (OA), and cyanotoxin microcystin-LR (MC-LR)-is for the first time developed. For this, a competitive indirect immunochromatographic analysis (ICA) based on gold-labeled secondary antibodies was carried out. The LODs/cutoffs/working ranges of the ICA were 0.05/0.3/0.07-0.29, 1.3/100/3.2-58.2, and 0.1/2.0/0.2-1.1 ng/mL for MC-LR, DA, and OA, respectively. The assay duration was 18 min. The developed test system was used to analyze water samples from natural sources (salt and fresh water) and fish samples. For sample preparation of water, simple dilution with a buffer was proposed; for fish samples, methanol-water extraction was utilized. It was demonstrated that the triple LFIA specifically detected target aquatic toxins with recoveries of 85.0-121.5%. The developed multiplex LFIA can be considered a promising analytical solution for the rapid, easy, and sensitive control of water and food safety.
(© 2022. Springer-Verlag GmbH Germany, part of Springer Nature.)
Databáze: MEDLINE
Nepřihlášeným uživatelům se plný text nezobrazuje