Push-Out Bond Strength Assessment of Different Post Systems at Different Radicular Levels of Endodontically Treated Teeth.

Autor: Kanzler Abdel Raouf V; Division of Dental Biomaterials, Clinic of Reconstructive Dentistry, Center of Dental Medicine, University of Zurich, 8032 Zurich, Switzerland., Jockusch J; University Research Priority Program Dynamics of Healthy Aging', University of Zurich, 8050 Zurich, Switzerland., Al-Haj Husain N; Division of Dental Biomaterials, Clinic of Reconstructive Dentistry, Center of Dental Medicine, University of Zurich, 8032 Zurich, Switzerland.; Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, 3010 Bern, Switzerland., Dydyk N; Division of Dental Biomaterials, Clinic of Reconstructive Dentistry, Center of Dental Medicine, University of Zurich, 8032 Zurich, Switzerland.; Department of Prosthetic Dentistry, Danylo Halytskyy Lviv National Medical University, 79010 Lviv, Ukraine., Özcan M; Division of Dental Biomaterials, Clinic of Reconstructive Dentistry, Center of Dental Medicine, University of Zurich, 8032 Zurich, Switzerland.
Jazyk: angličtina
Zdroj: Materials (Basel, Switzerland) [Materials (Basel)] 2022 Jul 24; Vol. 15 (15). Date of Electronic Publication: 2022 Jul 24.
DOI: 10.3390/ma15155134
Abstrakt: This study assessed the bond strength of prefabricated post systems at different root levels of endodontically treated teeth. One-rooted human premolars (N = 70; n = 10) were cut to 2 mm above the cement-enamel junction. Root canals were treated and randomly assigned to one of the seven post systems: T: Titanium (Mooser), ZrO: Zirconia (Cosmopost), G: Fiber (FRC Postec Plus), E1: Fiber (Direct) (Everstick post), E2: Fiber (Indirect) (Everstick post), PP: Fiber (PinPost), and LP: Injectable Resin/Fiber composite (EverX Posterior). All posts were luted using a resin cement (Variolink II), and the roots were sectioned at the coronal, middle, and apical root levels. Push-out tests were performed in the Universal Testing Machine (0.5 mm/min). Data (MPa) were analyzed using two-way ANOVA and Tukey's tests (α = 0.05). The results showed that the bond strength (mean ± SD) of E2 posts were highest (5.3 ± 2.7) followed by PP (4.1 ± 2.0); G (4.0 ± 1.6); LP (2.6 ± 1.9): T (2.2 ± 1.5) and ZrO (1.9 ± 1.0) posts systems. No significant differences were found in bond strength of all post systems. The bond strength in the coronal root level was the highest with 3.6 ± 2.2 MPa. The bond strength of FRC post systems was significantly higher than those of rigid posts of titanium or ZrO 2 . Bond strength results were the highest in the coronal root level for all tested post systems but did not differ significantly from the other two root levels.
Databáze: MEDLINE
Nepřihlášeným uživatelům se plný text nezobrazuje