Using High-Resolution Ultrasound to Assess Post-Facial Paralysis Synkinesis-Machine Settings and Technical Aspects for Facial Surgeons.
Autor: | Kehrer A; Department of Plastic, Hand and Reconstructive Surgery, University Hospital Regensburg, 93053 Regensburg, Germany., Ruewe M; Department of Plastic, Hand and Reconstructive Surgery, University Hospital Regensburg, 93053 Regensburg, Germany., Platz Batista da Silva N; Department of Radiology, University Hospital Regensburg, 93053 Regensburg, Germany., Lonic D; Department of Plastic, Hand and Reconstructive Surgery, University Hospital Regensburg, 93053 Regensburg, Germany., Heidekrueger PI; Department of Plastic, Hand and Reconstructive Surgery, University Hospital Regensburg, 93053 Regensburg, Germany., Knoedler S; Department of Plastic Surgery and Hand Surgery, Klinikum Rechts der Isar, Technical University of Munich, 81675 Munich, Germany., Jung EM; Department of Radiology, University Hospital Regensburg, 93053 Regensburg, Germany., Prantl L; Department of Plastic, Hand and Reconstructive Surgery, University Hospital Regensburg, 93053 Regensburg, Germany., Knoedler L; Department of Plastic, Hand and Reconstructive Surgery, University Hospital Regensburg, 93053 Regensburg, Germany. |
---|---|
Jazyk: | angličtina |
Zdroj: | Diagnostics (Basel, Switzerland) [Diagnostics (Basel)] 2022 Jul 07; Vol. 12 (7). Date of Electronic Publication: 2022 Jul 07. |
DOI: | 10.3390/diagnostics12071650 |
Abstrakt: | Background: Synkinesis of the facial musculature is a detrimental sequalae in post-paralytic facial palsy (PPFP) patients. Detailed knowledge on the technical requirements and device properties in a high-resolution ultrasound (HRUS) examination is mandatory for a reliable facial muscle assessment in PPFP patients. We therefore aimed to outline the key steps in a HRUS examination and extract an optimized workflow schema. Methods: From December 2020 to April 2021, 20 patients with unilateral synkinesis underwent HRUS. All HRUS examinations were performed by the first author using US devices with linear multifrequency transducers of 4-18 MHz, including a LOGIQ E9 and a LOGIQ S7 XDclear (GE Healthcare; Milwaukee, WI, USA), as well as Philips Affinity 50G (Philips Health Systems; Eindhoven, the Netherlands). Results: Higher-frequency and multifrequency linear probes ≥15 MHz provided superior imaging qualities. The selection of the preset program Small Parts, Breast or Thyroid was linked with a more detailed contrast of the imaging morphology of facial tissue layers. Frequency (Frq) = 15 MHz, Gain (Gn) = 25-35 db, Depth (D) = 1-1.5 cm, and Focus (F) = 0.5 cm enhanced the image quality and assessability. Conclusions: An optimized HRUS examination protocol for quantitative and qualitative facial muscle assessments was proposed. |
Databáze: | MEDLINE |
Externí odkaz: | |
Nepřihlášeným uživatelům se plný text nezobrazuje | K zobrazení výsledku je třeba se přihlásit. |