Atmospheric Pressure Mass Spectrometry of Single Viruses and Nanoparticles by Nanoelectromechanical Systems.

Autor: Erdogan RT, Alkhaled M, Kaynak BE, Alhmoud H, Pisheh HS, Kelleci M, Karakurt I, Yanik C; Sabancı University, SUNUM Nanotechnology Research and Application Center, 34956 Istanbul, Turkey., Şen ZB, Sari B; Faculty of Engineering and Natural Sciences, Sabancı University, 34956 Istanbul, Turkey., Yagci AM; METU MEMS Center, 06530 Ankara, Turkey., Özkul A; Faculty of Veterinary Medicine, Department of Virology, Ankara University, 06110 Ankara, Turkey.; Biotechnology Institute, Ankara University, 06135 Ankara, Turkey., Hanay MS
Jazyk: angličtina
Zdroj: ACS nano [ACS Nano] 2022 Mar 22; Vol. 16 (3), pp. 3821-3833. Date of Electronic Publication: 2022 Jan 04.
DOI: 10.1021/acsnano.1c08423
Abstrakt: Mass spectrometry of intact nanoparticles and viruses can serve as a potent characterization tool for material science and biophysics. Inaccessible by widespread commercial techniques, the mass of single nanoparticles and viruses (>10MDa) can be readily measured by nanoelectromechanical systems (NEMS)-based mass spectrometry, where charged and isolated analyte particles are generated by electrospray ionization (ESI) in air and transported onto the NEMS resonator for capture and detection. However, the applicability of NEMS as a practical solution is hindered by their miniscule surface area, which results in poor limit-of-detection and low capture efficiency values. Another hindrance is the necessity to house the NEMS inside complex vacuum systems, which is required in part to focus analytes toward the miniscule detection surface of the NEMS. Here, we overcome both limitations by integrating an ion lens onto the NEMS chip. The ion lens is composed of a polymer layer, which charges up by receiving part of the ions incoming from the ESI tip and consequently starts to focus the analytes toward an open window aligned with the active area of the NEMS electrostatically. With this integrated system, we have detected the mass of gold and polystyrene nanoparticles under ambient conditions and with two orders-of-magnitude improvement in capture efficiency compared to the state-of-the-art. We then applied this technology to obtain the mass spectrum of SARS-CoV-2 and BoHV-1 virions. With the increase in analytical throughput, the simplicity of the overall setup, and the operation capability under ambient conditions, the technique demonstrates that NEMS mass spectrometry can be deployed for mass detection of engineered nanoparticles and biological samples efficiently.
Databáze: MEDLINE