Effect of a polymerization inhibitor on the chemomechanical properties and consistency of experimental resin composites.

Autor: Grohmann CVS; Department of Restorative Dentistry, Dental Materials Division, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil., Sinhoreti MAC; Department of Restorative Dentistry, Dental Materials Division, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil., Soares EF; Department of Restorative Dentistry, Dental Materials Division, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil., Oliveira RF; Department of Restorative Dentistry, Dental Materials Division, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil., Souza-Júnior EJC; Department of Restorative Dentistry, Dental Materials Division, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil., Geraldeli S; Division of Biomedical Materials, School of Dental Medicine, East Carolina University, Greenville, NC, USA.
Jazyk: angličtina
Zdroj: Brazilian dental journal [Braz Dent J] 2022 May-Jun; Vol. 33 (3), pp. 92-98.
DOI: 10.1590/0103-6440202204242
Abstrakt: This study investigated the effect of butylated hydroxytoluene (BHT) inhibitor on degree of conversion (DC), flexural strength (FS), flexural modulus (FM), Knoop microhardness (KH), microhardness reduction (HR), and consistency of experimental resin composites at different BHT concentrations: C0 (control-0%); C0.01 (0.01%); C0.025 (0.025%); C0.05 (0.05%); C0.1 (0.1%); and C0.5 (0.5%). For the consistency, the composites were tested immediately after being exposed to a dental chair headlight (0, 20, 40 and 60 s). Data concerning DC, FS, FM, KH, and HR were submitted to one-way ANOVA, while the consistency data was submitted to 2-way ANOVA; mean values were then compared (Tukey's test; α=0.05). The KH, FS and FM analyses showed no significant difference among the composites tested. For DC, C0 showed the highest mean value (74.2%) and differed only from C0.5 (67.2%). For HR, C0.5 showed the lowest mean (13.09%) value and differed from C0 (26.4%) and C0.01 (24.87). The consistency analysis showed no difference among C0.05, C0.1 and C0.5, considering 0 and 20 s of light exposure, while C0 (14.07 mm), C0.01 (13.97 mm), and C0.025 (14.18 mm) showed higher mean values at 0 s when compared to 20 s (12.67, 12.77 and 13.05 mm, respectivelly). Polymerization occurred within 40 s of light exposure for C0, C0.01, C0.025, and C0.05 and within 60 s for C0.1. In conclusion, the BHT concentrations had no significant influence on FS, FM and KH. The higher the BHT concentration, the longer was its handling time under light, with a significant improvement in the HR, but a decrease in DC. Therefore, BHT at 0.1% showed the best outcomes concerning all the BHT concentrations tested.
Databáze: MEDLINE