Safety verification of a new peripheral intravenous catheter placed in the upper arm vein for administration of drugs with high irritant potential.

Autor: Murayama R; Department of Advanced Nursing Technology, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan.; Global Nursing Research Center, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan., Oyama H; Department of Gerontological Nursing/Wound Care Management, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan., Abe-Doi M; Department of Advanced Nursing Technology, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan., Masamoto Y; Department of Hematology and Oncology, The University of Tokyo Hospital, Tokyo, Japan., Kashiwabara K; Clinical Research Promotion Center, The University of Tokyo Hospital, Tokyo, Japan., Tobe H; Global Nursing Research Center, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan., Komiyama C; Nursing Department, The University of Tokyo Hospital, Tokyo, Japan., Sanada H; Global Nursing Research Center, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan.; Department of Gerontological Nursing/Wound Care Management, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan., Kurokawa M; Department of Hematology and Oncology, The University of Tokyo Hospital, Tokyo, Japan.
Jazyk: angličtina
Zdroj: Drug discoveries & therapeutics [Drug Discov Ther] 2022 Jul 20; Vol. 16 (3), pp. 128-134. Date of Electronic Publication: 2022 Jun 25.
DOI: 10.5582/ddt.2022.01034
Abstrakt: Despite the widespread use of peripheral intravenous catheters, unscheduled catheter failure before completion of treatment occurs frequently. If a large vein is selected, catheter failures may be prevented despite administering a highly irritant drug. In this study, we attempted to use a catheter that can be placed in a large upper arm vein. The new catheter was 88 mm long but had no guidewire to reduce contamination risk. This study aimed to evaluate the safety of the first-in-human trial for the new catheter with the administration of highly irritant drugs. This study was conducted at a university hospital in Tokyo, Japan. Eight Japanese adults were hospitalized adults with planned administration of non-cancer drugs with high irritant potential using a peripheral catheter. A trained nurse catheterized with the new catheter in the upper arm using ultrasonography. The catheterization site was monitored by staff and a research nurse once every 24 hours for up to 7 days. No adverse events or catheter failure occurred and the catheter placement success rate was 100%. In two patients, a temporary occlusion alarm of the infusion pump occurred, possibly due to the flexion of the catheter base. The new peripheral intravenous catheter did not interrupt medical treatments as is common after placement, but safety administered the irritant drugs. However, because this catheter may be easily affected by the contraction of the muscle at the fixation position, the position and method of catheter fixation in the upper arm need to be carefully considered.
Databáze: MEDLINE