Low incidence of restenosis after successful balloon pulmonary angioplasty in patients with chronic thromboembolic pulmonary hypertension.

Autor: Tabuchi I; Department of Cardiology, National Hospital Organization Okayama Medical Center, 1711-1 Tamasu, Kita-ku, Okayama, 701-1192, Japan.; Department of Cardiovascular Medicine, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, 2-5-1 Shikata-cho, Kita-ku, Okayama, 700-8558, Japan., Ogawa A; Department of Clinical Science, National Hospital Organization Okayama Medical Center, 1711-1 Tamasu, Kita-ku, Okayama, 701-1192, Japan., Shigetoshi M; Department of Cardiology, National Hospital Organization Okayama Medical Center, 1711-1 Tamasu, Kita-ku, Okayama, 701-1192, Japan., Shimokawahara H; Department of Cardiology, National Hospital Organization Okayama Medical Center, 1711-1 Tamasu, Kita-ku, Okayama, 701-1192, Japan., Ito H; Department of Cardiovascular Medicine, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, 2-5-1 Shikata-cho, Kita-ku, Okayama, 700-8558, Japan., Matsubara H; Department of Cardiology, National Hospital Organization Okayama Medical Center, 1711-1 Tamasu, Kita-ku, Okayama, 701-1192, Japan. matsubara.hiromi@gmail.com.; Department of Clinical Science, National Hospital Organization Okayama Medical Center, 1711-1 Tamasu, Kita-ku, Okayama, 701-1192, Japan. matsubara.hiromi@gmail.com.
Jazyk: angličtina
Zdroj: Cardiovascular intervention and therapeutics [Cardiovasc Interv Ther] 2023 Apr; Vol. 38 (2), pp. 231-240. Date of Electronic Publication: 2022 Jun 22.
DOI: 10.1007/s12928-022-00866-y
Abstrakt: Balloon pulmonary angioplasty (BPA) is now a treatment option for patients with inoperable chronic thromboembolic pulmonary hypertension (CTEPH). However, the incidence of restenosis and long-term changes in vessel diameters in pulmonary arteries after BPA are unknown. The present study investigated the incidence of restenosis by measuring changes in vessel diameter after BPA. We reviewed 58 patients (168 lesions) with CTEPH who underwent single dilation for the target lesion (type A/B/C lesions) during BPA procedure followed by selective pulmonary angiography more than 6 months after the final BPA procedure. The outcomes of BPA were assessed in terms of pulmonary artery diameters. In a median follow-up of 1.9 (1.2-2.7) years, restenosis occurred in only one case with a type C lesion after BPA (0.6%). In type A/B lesions, the minimal lumen diameter was significantly enlarged at follow-up after BPA [3.48 (2.59-4.34) to 4.22 (3.31-4.90) mm]. In type C lesions, the minimal lumen diameter was unchanged at follow-up after BPA [3.15 (1.96-3.64) to 3.28 (2.38-4.61) mm]. The present results revealed that restenosis after BPA rarely occurs in type A/B/C lesions. Minimal lumen diameters for type A/B lesions continually increased and those for type C lesions did not decrease. Stent implantation in type A/B/C lesions would be unnecessary after BPA.
(© 2022. The Author(s) under exclusive licence to Japanese Association of Cardiovascular Intervention and Therapeutics.)
Databáze: MEDLINE