The DERIVO 2heal embolisation device: A technical report using single antiplatelet therapy for intracranial pseudoaneurysm treatment.

Autor: Goertz L; Faculty of Medicine and University Hospital, Department of Radiology and Neuroradiology, University of Cologne, Cologne, Germany., Schoenfeld M; Faculty of Medicine and University Hospital, Department of Radiology and Neuroradiology, University of Cologne, Cologne, Germany., Zopfs D; Faculty of Medicine and University Hospital, Department of Radiology and Neuroradiology, University of Cologne, Cologne, Germany., Lüers JC; Faculty of Medicine and University Hospital, Department of Otorhinolaryngology, University of Cologne, Cologne, Germany., Schlamann M; Faculty of Medicine and University Hospital, Department of Radiology and Neuroradiology, University of Cologne, Cologne, Germany., Kabbasch C; Faculty of Medicine and University Hospital, Department of Radiology and Neuroradiology, University of Cologne, Cologne, Germany.
Jazyk: angličtina
Zdroj: Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences [Interv Neuroradiol] 2024 Apr; Vol. 30 (2), pp. 170-174. Date of Electronic Publication: 2022 Jun 06.
DOI: 10.1177/15910199221104620
Abstrakt: The novel DERIVO 2heal Embolisation Device (Acandis, Pforzheim, Germany) is a flexible, fully radiopaque flow-diverter with a fibrin-based nano-coating, which is supposed to make the device inert to the coagulation cascade. We report a case of pseudoaneurysm treatment with this device under single anti-platelet therapy (SAPT). A female patient underwent endoscopic surgery for chronic rhinosinusitis. During surgery, the lateral wall of the sphenoid wall and the adjacent internal carotid artery was injured, leading to massive hemorrhage, which was treated with compression and tamponades. Eleven days after the procedure, the patient developed a rapidly growing pseudoaneurysm at the injury site with a relevant risk of upcoming aneurysm rupture. The aneurysm was treated by implantation of a DERIVO 2heal. A SAPT regimen was chosen due to the recent massive hemorrhage and anticipating enhanced progressive aneurysm occlusion. There were no thromboembolic complications and there was no morbidity. After 5 days, the pseudoaneurysm was completely occluded. The observations of the presented case are promising and warrant further investigation of this device.
Competing Interests: Declaration of conflicting interestsThe author(s) declared the following potential conflicts of interest with respect to the research, authorship, and/or publication of this article: CK serves as consultant for Acandis GmbH (Pforzheim, Germany) and as proctor for MicroVention Inc./Sequent Medical (Aliso Viejo, CA, USA). DZ received research support from Philips Healthcare unrelated to this work. The other authors declare that there is no conflict of interest
Databáze: MEDLINE