A component could not be larger than the whole, polyclonal immunoglobulin interference in conjugated/direct bilirubin assay and elimination: A case report.
Autor: | Soleimani N; Department of Pathology Shiraz Medical School Shiraz University of Medical Sciences Shiraz Iran.; Department of Pathology Shiraz Transplant Center Abu Ali Sina Hospital Shiraz University of Medical Sciences Shiraz Iran., Khaleghpanah S; Department of Pathology Shiraz Medical School Shiraz University of Medical Sciences Shiraz Iran., Mohammadzadeh S; Department of Pathology Shiraz Medical School Shiraz University of Medical Sciences Shiraz Iran.; Department of Pathology Shiraz Transplant Center Abu Ali Sina Hospital Shiraz University of Medical Sciences Shiraz Iran. |
---|---|
Jazyk: | angličtina |
Zdroj: | Clinical case reports [Clin Case Rep] 2022 May 15; Vol. 10 (5), pp. e05870. Date of Electronic Publication: 2022 May 15 (Print Publication: 2022). |
DOI: | 10.1002/ccr3.5870 |
Abstrakt: | Analytical interferences (hemolysis, icterus, paraproteinemia, and lipemia) are of great concern in laboratory tests. In our case report, the conjugated bilirubin result of a patient was significantly higher than the total bilirubin. We recommend being more cautious with samples that produce indistinguishable results and attempting to resolve the issues before releasing them. Competing Interests: The authors declare that they have no competing interests. (© 2022 The Authors. Clinical Case Reports published by John Wiley & Sons Ltd.) |
Databáze: | MEDLINE |
Externí odkaz: | |
Nepřihlášeným uživatelům se plný text nezobrazuje | K zobrazení výsledku je třeba se přihlásit. |