Evaluation of rapid antigen detection kits for detection of SARS-CoV-2 B.1.617.2 virus.
Autor: | Mak GC; Microbiology Division, Public Health Laboratory Services Branch, Centre for Health Protection, Department of Health, Hong Kong Special Administrative Region, China., Lau SS; Microbiology Division, Public Health Laboratory Services Branch, Centre for Health Protection, Department of Health, Hong Kong Special Administrative Region, China., Wong KK; Microbiology Division, Public Health Laboratory Services Branch, Centre for Health Protection, Department of Health, Hong Kong Special Administrative Region, China., Chow NL; Microbiology Division, Public Health Laboratory Services Branch, Centre for Health Protection, Department of Health, Hong Kong Special Administrative Region, China., Lau CS; Microbiology Division, Public Health Laboratory Services Branch, Centre for Health Protection, Department of Health, Hong Kong Special Administrative Region, China., Lam ET; Microbiology Division, Public Health Laboratory Services Branch, Centre for Health Protection, Department of Health, Hong Kong Special Administrative Region, China., Ng KH; Microbiology Division, Public Health Laboratory Services Branch, Centre for Health Protection, Department of Health, Hong Kong Special Administrative Region, China., Chan RC; Microbiology Division, Public Health Laboratory Services Branch, Centre for Health Protection, Department of Health, Hong Kong Special Administrative Region, China. |
---|---|
Jazyk: | angličtina |
Zdroj: | Future virology [Future Virol] 2022 Mar. Date of Electronic Publication: 2022 Apr 11. |
DOI: | 10.2217/fvl-2021-0229 |
Abstrakt: | Aim: Currently, there is lack of data regarding rapid antigen detection (RAD) kits to detect SARS-CoV-2 B.1.617.2 virus. Objective: The purpose of this evaluation is to assess analytical sensitivity of 12 RAD kits against SARS-CoV-2 B.1.617.2. Study design: Analytical sensitivity was determined by limit of detection (LOD). A serial tenfold dilution set from a respiratory specimen collected from a COVID-19 patient infected by SARS-CoV-2 B.1.617.2 was used. RT-PCR was used as a reference method. Results: The LOD results showed that 11 and one RAD kits were 100- and 1000-fold less sensitive than RT-PCR respectively. Conclusion: The results showed that the RAD kits evaluated in this study may be used for first-line screening of the SARS-CoV-2 B.1.617.2 variant. (© 2022 Future Medicine Ltd.) |
Databáze: | MEDLINE |
Externí odkaz: |