Bone remodeling around dental implants after 1-1.5 years of functional loading: A retrospective analysis of two-stage implants.
Autor: | Maghsoudi P; Department for Periodontology, Academic Centre for Dentistry Amsterdam (ACTA), a joint venture between the Faculty of Dentistry of the University of Amsterdam and Vrije Universiteit Amsterdam, Amsterdam, The Netherlands., Slot DE; Department for Periodontology, Academic Centre for Dentistry Amsterdam (ACTA), a joint venture between the Faculty of Dentistry of the University of Amsterdam and Vrije Universiteit Amsterdam, Amsterdam, The Netherlands., van der Weijden FGA; Department for Periodontology, Academic Centre for Dentistry Amsterdam (ACTA), a joint venture between the Faculty of Dentistry of the University of Amsterdam and Vrije Universiteit Amsterdam, Amsterdam, The Netherlands.; Clinic for Implantology Utrecht, Utrecht, The Netherlands. |
---|---|
Jazyk: | angličtina |
Zdroj: | Clinical and experimental dental research [Clin Exp Dent Res] 2022 Jun; Vol. 8 (3), pp. 680-689. Date of Electronic Publication: 2022 Apr 15. |
DOI: | 10.1002/cre2.574 |
Abstrakt: | Objectives: This study aims to retrospectively assess to what extent peri-implant bone level changes occur from exposing the implant to the oral environment at the second stage of surgery (SSS) to the baseline assessment and, additionally, after 1-1.5 years of functional loading. Further, this study aims to examine the role of the emergence angle in marginal bone changes. Material and Methods: This retrospective study included 46 patients treated between 2012 and 2019. These patients received 64 bone-level dental implants. After implant placement, SSS, and baseline assessment, relevant clinical peri-implant conditions and radiographical data were collected. A radiographic examination of the marginal bone level was performed after SSS, the baseline assessment, and 1-1.5 years of follow-up. Results: The peri-implant periodontal probing depth increased significantly from 3.08 ± 0.7 mm at the baseline to 3.27 ± 0.81 mm at the 1-1.5-year follow-up. The mean marginal bone level at the implant level was 0.12 ± 0.23, 0.35 ± 0.43, and 0.47 ± 0.47 mm at the SSS, baseline, and the 1-1.5-year follow-up, respectively. Most changes occurred at the implant's distal site. A significant relationship was found between the emergence angle and the extent of change in the marginal bone level between the SSS and baseline (r = .430, p ≤ .001). Conclusions: Most changes in the marginal bone level occurred between SSS and baseline assessments. For diagnostic purposes, it is advised to obtain a standardized radiograph after SSS to monitor peri-implant bone-level alterations. (© 2022 The Authors. Clinical and Experimental Dental Research published by John Wiley & Sons Ltd.) |
Databáze: | MEDLINE |
Externí odkaz: |