Myopic LASIK Outcomes: Comparison of Three Different Femtosecond Lasers and a Mechanical Microkeratome Using the Same Excimer Laser.
Autor: | Gros-Otero J; Clínica Rementería, Madrid, Spain., Rodríguez-Pérez I; Clínica Novovisión, Paseo de la Castellana 54, 28046, Madrid, Spain. isaymaimonides@gmail.com., Teus MA; Clínica Novovisión, Paseo de la Castellana 54, 28046, Madrid, Spain.; Hospital Universitario 'Príncipe de Asturias', University of Alcalá, Alcalá de Henares, Madrid, Spain., Katsanos A; Department of Ophthalmology, University of Ioannina, Ioannina, Greece., Mikropoulos DG; 3rd University Department of Ophthalmology, Aristotle University of Thessaloniki, Thessaloniki, Greece., García-González M; Clínica Rementería, Madrid, Spain.; Clínica Novovisión, Paseo de la Castellana 54, 28046, Madrid, Spain. |
---|---|
Jazyk: | angličtina |
Zdroj: | Ophthalmology and therapy [Ophthalmol Ther] 2022 Jun; Vol. 11 (3), pp. 1047-1066. Date of Electronic Publication: 2022 Mar 09. |
DOI: | 10.1007/s40123-022-00486-y |
Abstrakt: | Introduction: To compare the influence of one microkeratome and three femtosecond lasers on myopic laser in situ keratomileusis (LASIK) outcomes. Methods: Retrospective, observational cohort study. We compared 134 eyes treated with the IntraLase 60 kHz, 112 eyes treated with the Femto LDV Z6, 206 eyes treated with the FS200, and 98 eyes treated with the Hansatome zero compression microkeratome. All eyes were operated on using the same surgical protocol with the same excimer laser (Wavelight Allegretto) and were allocated to refraction-matched groups. Results: One day and one week postoperatively, uncorrected distance visual acuity was significantly lower in the FS200 group compared to others (P = 0.0001). This difference disappeared at the 1- and 3-month postoperative visits. Significant differences were found among groups in terms of safety index (P = 0.0001), residual sphere (P = 0.0001), and residual cylinder (P = 0.02) at the 3-month postoperative visit. No significant differences were found in corrected distance visual acuity or efficacy index. Conclusion: According to our results, a slight delay in visual restoration after FS200 LASIK surgery might be expected. This delay was statistically significant at 1 day and 1 week postoperatively, but there were no differences from the 1-month visit onwards. Additionally, significant differences were found among devices in terms of safety index and the refractive results, which were found not to be clinically relevant. (© 2022. The Author(s).) |
Databáze: | MEDLINE |
Externí odkaz: | |
Nepřihlášeným uživatelům se plný text nezobrazuje | K zobrazení výsledku je třeba se přihlásit. |