Objective Perfusion Assessment in Gracilis Muscle Interposition-A Novel Software-Based Approach to Indocyanine Green Derived Near-Infrared Fluorescence in Reconstructive Surgery.
Autor: | Lobbes LA; Department of General and Visceral Surgery, Hindenburgdamm 30, Charité-Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, 12203 Berlin, Germany., Hoveling RJM; Quest Medical Imaging, 1775 PW Middenmeer, The Netherlands., Schmidt LR; Department of General and Visceral Surgery, Hindenburgdamm 30, Charité-Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, 12203 Berlin, Germany., Berns S; Department of General and Visceral Surgery, Hindenburgdamm 30, Charité-Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, 12203 Berlin, Germany., Weixler B; Department of General and Visceral Surgery, Hindenburgdamm 30, Charité-Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, 12203 Berlin, Germany. |
---|---|
Jazyk: | angličtina |
Zdroj: | Life (Basel, Switzerland) [Life (Basel)] 2022 Feb 13; Vol. 12 (2). Date of Electronic Publication: 2022 Feb 13. |
DOI: | 10.3390/life12020278 |
Abstrakt: | Background: Gracilis muscle interposition (GMI) is an established treatment option for complex perineal fistulas and reconstruction. The outcome is limited by complications such as necrosis, impaired wound healing and fistula persistence or recurrence. Quantifiable methods of assessing muscle flap perfusion intraoperatively are lacking. This study evaluates a novel and objective software-based assessment of indocyanine green near-infrared fluorescence (ICG-NIRF) in GMI. Methods: Intraoperative ICG-NIRF visualization data of five patients with inflammatory bowel disease (IBD) undergoing GMI for perineal fistula and reconstruction were analyzed retrospectively. A new software was utilized to generate perfusion curves for the specific regions of interest (ROIs) of each GMI by depicting the fluorescence intensity over time. Additionally, a pixel-to-pixel and perfusion zone analysis were performed. The findings were correlated with the clinical outcome. Results: Four patients underwent GMI without postoperative complications within 3 months. The novel perfusion indicators identified here (shape of the perfusion curve, maximum slope value, distribution and range) indicated adequate perfusion. In one patient, GMI failed. In this case, the perfusion indicators suggested impaired perfusion. Conclusions: We present a novel, software-based approach for ICG-NIRF perfusion assessment, identifying previously unknown objective indicators of muscle flap perfusion. Ready for intraoperative real-time use, this method has considerable potential to optimize GMI surgery in the future. |
Databáze: | MEDLINE |
Externí odkaz: | |
Nepřihlášeným uživatelům se plný text nezobrazuje | K zobrazení výsledku je třeba se přihlásit. |