Intra-assessor reliability and measurement error of ultrasound measures for foot muscle morphology in older adults using a tablet-based ultrasound machine.
Autor: | Willemse L; Department of Health Innovations and Technology, Fontys University of Applied Sciences, PO Box 347, 5600 AH, Eindhoven, Netherlands. lydia.willemse@fontys.nl.; Department of Movement Sciences, KU Leuven, Tervuursevest 101 - box 1500, 3001, Leuven, Belgium. lydia.willemse@fontys.nl.; Tranzo, School of Social and Behavioral Sciences, Tilburg University, PO Box 90153, 5000 LE, Tilburg, Netherlands. lydia.willemse@fontys.nl., Wouters EJM; Department of Health Innovations and Technology, Fontys University of Applied Sciences, PO Box 347, 5600 AH, Eindhoven, Netherlands.; Tranzo, School of Social and Behavioral Sciences, Tilburg University, PO Box 90153, 5000 LE, Tilburg, Netherlands., Pisters MF; Department of Health Innovations and Technology, Fontys University of Applied Sciences, PO Box 347, 5600 AH, Eindhoven, Netherlands.; Department of Rehabilitation, Physiotherapy Science & Sport, UMC Utrecht Brain Center, Utrecht University, PO Box 85500, 3508 GA, Utrecht, The Netherlands.; Center for Physical Therapy Research and Innovation in Primary Care, Julius Health Care Centers, PO Box 85500, 3508 GA, Utrecht, Netherlands., Vanwanseele B; Department of Health Innovations and Technology, Fontys University of Applied Sciences, PO Box 347, 5600 AH, Eindhoven, Netherlands.; Department of Movement Sciences, KU Leuven, Tervuursevest 101 - box 1500, 3001, Leuven, Belgium. |
---|---|
Jazyk: | angličtina |
Zdroj: | Journal of foot and ankle research [J Foot Ankle Res] 2022 Jan 25; Vol. 15 (1), pp. 6. Date of Electronic Publication: 2022 Jan 25. |
DOI: | 10.1186/s13047-022-00510-1 |
Abstrakt: | Background: To gain insight into the role of plantar intrinsic foot muscles in fall-related gait parameters in older adults, it is fundamental to assess foot muscles separately. Ultrasonography is considered a promising instrument to quantify the strength capacity of individual muscles by assessing their morphology. The main goal of this study was to investigate the intra-assessor reliability and measurement error for ultrasound measures for the morphology of selected foot muscles and the plantar fascia in older adults using a tablet-based device. The secondary aim was to compare the measurement error between older and younger adults and between two different ultrasound machines. Methods: Ultrasound images of selected foot muscles and the plantar fascia were collected in younger and older adults by a single operator, intensively trained in scanning the foot muscles, on two occasions, 1-8 days apart, using a tablet-based and a mainframe system. The intra-assessor reliability and standard error of measurement for the cross-sectional area and/or thickness were assessed by analysis of variance. The error variance was statistically compared across age groups and machines. Results: Eighteen physically active older adults (mean age 73.8 (SD: 4.9) years) and ten younger adults (mean age 21.9 (SD: 1.8) years) participated in the study. In older adults, the standard error of measurement ranged from 2.8 to 11.9%. The ICC ranged from 0.57 to 0.97, but was excellent in most cases. The error variance for six morphology measures was statistically smaller in younger adults, but was small in older adults as well. When different error variances were observed across machines, overall, the tablet-based device showed superior repeatability. Conclusions: This intra-assessor reliability study showed that a tablet-based ultrasound machine can be reliably used to assess the morphology of selected foot muscles in older adults, with the exception of plantar fascia thickness. Although the measurement errors were sometimes smaller in younger adults, they seem adequate in older adults to detect group mean hypertrophy as a response to training. A tablet-based ultrasound device seems to be a reliable alternative to a mainframe system. This advocates its use when foot muscle morphology in older adults is of interest. (© 2022. The Author(s).) |
Databáze: | MEDLINE |
Externí odkaz: | |
Nepřihlášeným uživatelům se plný text nezobrazuje | K zobrazení výsledku je třeba se přihlásit. |