Planar EPID-Based Dosimetry for SRS and SRT Patient-Specific QA.

Autor: Thongsawad S; Faculty of Medicine and Public Health, HRH Princess Chulabhorn College of Medical Science, Chulabhorn Royal Academy, Bangkok 10210, Thailand.; Department of Radiation Oncology, Chulabhorn Hospital, Chulabhorn Royal Academy, Bangkok 10210, Thailand., Chanton T; Department of Radiological Technology, Faculty of Allied Health Sciences, Naresuan University, Phitsanulok 65000, Thailand., Saiyo N; Department of Radiation Oncology, Chulabhorn Hospital, Chulabhorn Royal Academy, Bangkok 10210, Thailand.; Faculty of Health Science Technology, HRH Princess Chulabhorn College of Medical Science, Chulabhorn Royal Academy, Bangkok 10210, Thailand., Udee N; Department of Radiological Technology, Faculty of Allied Health Sciences, Naresuan University, Phitsanulok 65000, Thailand.
Jazyk: angličtina
Zdroj: Life (Basel, Switzerland) [Life (Basel)] 2021 Oct 30; Vol. 11 (11). Date of Electronic Publication: 2021 Oct 30.
DOI: 10.3390/life11111159
Abstrakt: The study's purpose was to develop and validate Electronic Portal Imaging Device (EPID)-based dosimetry for Stereotactic Radiosurgery (SRS) and Stereotactic Radiation Therapy (SRT) patient-specific Quality Assurance (QA). The co-operation between extended Source-to-Imager Distance (SID) to reduce the saturation effect and simplify the EPID-based dosimetry model was used to perform patient-specific QA in SRS and SRT plans. The four parameters were included for converting the image to dose at depth 10 cm; dose-response linearity with MU, beam profile correction, collimator scatter and water kernel. The model accuracy was validated with 10 SRS/SRT plans. The traditional diode arrays with MapCHECK were also used to perform patient-specific QA for assuring model accuracy. The 150 cm-SID was found a possibility to reduce the saturation effect. The result of model accuracy was found good agreement between our EPID-based dosimetry and TPS calculation with GPR more than 98% for gamma criteria of 3%/3 mm, more than 95% for gamma criteria of 2%/2 mm, and the results related to the measurement with MapCHECK. This study demonstrated the method to perform SRT and SRT patient-specific QA using EPID-based dosimetry in the FFF beam by co-operating between the extended SID that can reduce the saturation effect and estimate the planar dose distribution with the in-house model.
Databáze: MEDLINE
Nepřihlášeným uživatelům se plný text nezobrazuje