Digital workflow and virtual validation of a 3D-printed definitive hollow obturator for a large palatal defect.
Autor: | Jamayet NB; Senior Lecturer in Prosthodontics, Division of Restorative Dentistry, School of Dentistry, International Medical University, Kuala Lumpur, Malaysia. Electronic address: dr.nafij@gmail.com., Farook TH; Research Fellow, Maxillofacial Prosthetic Service, Prosthodontic Unit, School of Dental Sciences, Health Campus, Universiti Sains Malaysia, Kota Bharu, Kelantan, Malaysia., Al-Oulabi A; Clinical Fellow, Prosthodontic Unit, School of Dental Sciences, Health Campus, Universiti Sains Malaysia, Kota Bharu, Kelantan, Malaysia., Johari Y; Senior Lecturer in Prosthodontics, School of Dental Sciences, Health Campus, Universiti Sains Malaysia, Kota Bharu, Kelantan, Malaysia., Patil PG; Senior Lecturer in Prosthodontics, Division of Restorative Dentistry, School of Dentistry, International Medical University, Kuala Lumpur, Malaysia. |
---|---|
Jazyk: | angličtina |
Zdroj: | The Journal of prosthetic dentistry [J Prosthet Dent] 2023 May; Vol. 129 (5), pp. 798-804. Date of Electronic Publication: 2021 Oct 09. |
DOI: | 10.1016/j.prosdent.2021.08.021 |
Abstrakt: | This clinical report describes how a hollow obturator prosthesis was designed and fabricated for an 82-year-old partially edentulous patient with a large palatal defect. Computer-aided design (CAD) was used to design, articulate, and align the mandibular denture with the obturator prosthesis. The prosthesis was printed, adjusted chairside, rescanned, and made hollow by using a CAD software program. The prosthesis was printed in resin with a dental 3D printer. Quantitative evaluations of clinical (prosthesis dimensions, rest, and occlusal vertical dimensions) and virtual (surface area, volume, weight, interpoint mismatches, spatial overlap) parameters found that the 3D-printed prosthesis required an additional 5% chairside modification. The greatest differences in volume (24.7% less) and weight (22.2% less) were observed when the modified obturator bulb was made hollow via CAD. Hollowing the bulb, therefore, reduced the spatial overlap in volume by 16.8%. (Copyright © 2021 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.) |
Databáze: | MEDLINE |
Externí odkaz: |