The importance of first trimester screening of cranial posterior fossa in predicting posterior fossa malformations which may be identified in the following weeks of gestation.

Autor: Eric Ozdemir M; Perinatology Department, Health Science University, Zeynep Kamil Women and Children's Diseases Training and Research Hospital, Istanbul, Turkey., Demirci O; Perinatology Department, Health Science University, Zeynep Kamil Women and Children's Diseases Training and Research Hospital, Istanbul, Turkey., Ayvaci Tasan H; Perinatology Department, Health Science University, Zeynep Kamil Women and Children's Diseases Training and Research Hospital, Istanbul, Turkey., Ohanoglu K; Obstetrics and Gynaecology Department, Basaksehir Cam and Sakura City Hospital, Istanbul, Turkey., Akalin M; Perinatology Department, Health Science University, Zeynep Kamil Women and Children's Diseases Training and Research Hospital, Istanbul, Turkey.
Jazyk: angličtina
Zdroj: Journal of clinical ultrasound : JCU [J Clin Ultrasound] 2021 Nov; Vol. 49 (9), pp. 958-962. Date of Electronic Publication: 2021 Aug 17.
DOI: 10.1002/jcu.23057
Abstrakt: Purpose: We aimed to investigate the value of posterior fossa ultrasonography measurements in predicting fetal posterior fossa anomaly at 11-14 weeks of gestation.
Methods: The study was performed at Zeynep Kamil Women and Children's Diseases Training and Research Hospital. Measurements were made in two groups: the control group consisted of 328 fetuses with normal postnatal outcome and the study group consisted of 22 fetuses with enlarged 4 th ventricle. In the study group, we questioned the value of intracranial translucency (IT) and brainstem (BS) measurements and the BS/brainstem-to-occipital bone (BSOB) ratio in order to predict possible posterior fossa anomalies that may be identified in advanced gestational weeks. The differences of ultrasonographic measurements between groups with p < 0.05 were considered statistically significant.
Results: IT value, BSOB value, and BS/BSOB ratio were determined as ultrasonographic variables in predicting normal development of the fetal posterior fossa, with cutoff values of 2.7, 5.1, and 0.3. Negative predictive values of these three measurements for posterior fossa abnormalities were 100%. There was no statistically significant difference between the three variables for other diagnostic accuracy values (specifities and positive predictive values) (p > 0.05).
Conclusion: IT, BSOB, and BS/BSOB ratio can be used as ultrasonographic markers to predict the normal development of the fetal posterior fossa.
(© 2021 Wiley Periodicals LLC.)